Status Monitoring - pro bel 4407 Technical Manual

Digital audio sample rate converter
Table of Contents

Advertisement

4407
5

Status monitoring

The status monitoring circuit, will provide the following information to the status
monitoring controller:
·
module present
·
I/P 1 present
·
audio locked
·
SW 2 status
·
audio locked
In addition, the module is programmed with the following information, which can be
read by the status monitoring controller:
·
Module type
·
Module bar code
·
Module issue no
For further details of the Pro-Bel status monitoring system please refer to the
COSMOS status monitoring manual.