Tension DC
Calibre
Résolution
400 mV
0.1 mV
4 V
1 mV
40 V
10 mV
400 V
100 mV
600 V
1 V
Intensitée d´entrée: 10 MOhm
Tension AC (50...400 Hz)
Calibre
Résolution
4000 mV
1 mV
40 V
10 mV
400 V
100 mV
600 V
1 V
Intensitée d´entrée: 10 MOhm
Intensité DC
Calibre
Résolution
40 mA
0.01 mA
400 mA
0,1 mA
10,00 A
0,01 A
8 A continue,
10 A pendant 10 minutes maximum suivis d'une 20 minutes période de
refroidissement
Protection surcharge:
Fusibile (mA) :
FF500mA / 700V / 50kA , 6x32mm
Fusibile (A) :
F 10A/600V/50 kA, 6x32mm
10/26/06
9:50 AM
Page 11
Précision
Protec. surcahrge
± (0,8% d.L. +3D)
600 Veff
600 V
Précision
Protec. surcahrge
± (1,3% d.L. +5D)
600 Veff
Précision
± (1,5% d.L. +3 D)
± (2% d.L. +3 D)