  • Page 1 OWNER’S MANUAL Portable Air Conditioner KP-35 HN8 Thank you for purchasing our Portable Air Conditioner. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. READ AND SAVE THESE INSTRUCTIONS!
  • Page 2: Table Of Contents

    Contents Pr e p a r a t i o n ----------------------------------------------------------------------------------------- Safet y Pr e c a u t i o n s ----------------------------------------------------------------------------- Cau t i o n s----------------------------------------------------------------------------------------------- Installation--------------------------------------------------------------------------------------------- Operation ------------------------------------------------------------------------------------------------ Maintenance--- ----------------------------------------------------------------- --- F a u l t s Dia gnosi s -------------------------------------------------------------------------------------- De si gn and Compliance No t e s - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Soc i able Re m a rk -----------------------------------------------------------------------...
  • Page 3: Preparation

    Preparation control panel horizontal louver upper air filter blade (behind the grille) (swing automatically) handle (both sides) upper air intake drain outlet air outlet lower air filter Panel lower air intake drain outlet (only for pump heating mode) power cord outlet power cord buckle power plug socket Caster...
  • Page 4 Preparation NOTE: The unit you purchased may be look like one of the following(s):...
  • Page 5: Safety Precautions

    Safety Precautions This symbol indicates that ignoring instructions may cause death or serious injury. WARNING: To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage. -Installation must beeper formed according to the installation instructions.
  • Page 6: Cautions

    Cautions Cautions -This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play the appliance.
  • Page 7: Installation

    Installation Choosing The Right Location Your installation location should meet the following requirements: -Make sure that you install your unit on an even surface to minimize noise and vibration. -The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
  • Page 8 Installation Tools Needed -Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors; -Saw (optional, to shorten window adaptor for narrow windows) Accessories Your Window Installation Kit fits windows 67.5-123cm (26.5-48”) and can be shortened for smaller windows. Part Description Quantity Unit Adaptor 1 pc...
  • Page 9 Installation Note: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following three installation methods. Type 1: Hung Window Installation(optional) Foam seal B (Adhesive type-shorter) Window. Window slider B Foam seal A sliderA. (If required) (Adhesive type) Cut the adhesive foam seal A and B strips to the...
  • Page 10 Installation Foam seal C (Non-adhesive type Security Bracket 2 Screws If desired, install the security bracket with 2 screws as shown Cut the non-adhesive foam seal C strip to match the window height. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room.
  • Page 11: Operation

    Operation NOTE: On some models °F is instead of Swing button Used to initiate the Auto swing feature. When the operation is ON, press the SWING button can stop the louver at the desired angle. Timer button Used to initiate the AUTO ON start time and AUTO OFF stop time program, in conjunction with the + &...
  • Page 12 Operation Fan/Ion button (Ion is optional) Control the fan speed. Press to select the fan speed different fan in four steps-LOW, MID, HIGH and AUTO. The fan speed indicator light illuminates under settings except AUTO speed. When select AUTO fan speed, all the fan indicator lights turn dark. NOTE: Press this button for 3 seconds to initiate ION feature.
  • Page 13 Operation Operation Instructions COOL operation -Press the "MODE" button until the "COOL" indicator light comes on. -Press the ADJUST buttons "+" or "-" to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~88°F(or 86°F). -Press the "FAN SPEED"...
  • Page 14 Operation illuminates. Press the UP or down button to select the desired time. Press the TIMER button again within 5 seconds, the Auto-on start program is initiated. And the TIMER ON indicator light illuminates. Press the up or down button to select the desired Auto-on start time. -When the unit is off, press the Timer button to initiate the Auto-on start program, press it again within five seconds will initiate the Auto-off stop program.
  • Page 15 Operation AUTO-RESTART (on some models) If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes. WAIT 3 MINUTES BEFORE RESUMING OPERATION After the unit has stopped, it can not be restarted operation in the first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.
  • Page 16 Operation Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing. Place the end of the hose into he drain and make sure the end of the hose is down to let the water flow smoothly. (See Figs with .
  • Page 17: Maintenance

    Maintenance WARNING: -Always unplug the unit before cleaning or servicing. -DO NOT use flammable liquids or chemicals to clean the unit. -DO NOT wash the unit under running water. Doing so causes electrical danger. -DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
  • Page 18: Faults Diagnosis

    Faults Diagnosis Please check the machine according to the following form before asking for maintenance: Problem Possible Cause Troubleshooting Unit does not The Water Collection Tray is full. Turn off the unit, drain the water P1 Error Code from the Water Collection Tray and restart the unit. turn on when pressing ON/OFF In COOL mode: room temperature is lower than...
  • Page 19: Design And Compliance Notes

    Design and Compliance Notes Design Notice To ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice. Energy Rating Information The Energy Rating for this unit is based on an installation using an un-extended exhaust duct without window slider adaptor or wall exhaust adaptor A (as shown in the Installation section of this manual).
  • Page 20: Sociable Remark

    Sociable Remark When using this dehumidifier in the European countries, the following information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
  • Page 21 CP031IU-PD(DY)XBGF 16120600A1133X...