Advertisement

OWNER'S MANUAL
Portable Air Conditioner
KP-35 CP10
KP-35 CP11
KP-35 HP10
Thank you for purchasing our Portable Air Conditioner.
Before using your air conditioner, please read this instruction manual carefully and
keep it for future reference.
READ AND SAVE THESE INSTRUCTIONS!

Advertisement

Table of Contents
loading

Summary of Contents for Kaysun KP-35 CP11

  • Page 1 OWNER’S MANUAL Portable Air Conditioner KP-35 CP10 KP-35 CP11 KP-35 HP10 Thank you for purchasing our Portable Air Conditioner. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. READ AND SAVE THESE INSTRUCTIONS!
  • Page 2: Table Of Contents

    Contents Safety Precautions Cautions Warnings (for using R-290 refrigerant only) Preparations Installation Operation Maintenance Faults Diagnosis Design and Compliance Notes Sociable Remark...
  • Page 3: Safety Precautions

    Safety Precautions This symbol indicates that ignoring instructions may cause serious injury. WARNING: To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
  • Page 4: Cautions

    Cautions Cautions - This appliance can be used by children aged from 8 years and above and person with reduced phy- sical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5: Warnings (For Using R-290 Refrigerant Only)

    Warnings (for using R-290 refrigerant only) - Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. - The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • Page 6 Warnings (for using R-290 refrigerant only) 1. Transport of equipment containing flammable refrige- shall use any sources of ignition in such a manner that rants. it may lead to the risk of fire or explosion. All possible ignition sources, incluiding cigarrette smoking, should See transport regulations be kept sufficiently far away from the site of installa- 2.
  • Page 7 Warnings (for using R-290 refrigerant only) That there no live electrical components and wiring Electronic leak detectors shall be used to detect flam- are exposed while charging, recovering or purging the mable refrigerants, but the sensitivity may not be ade- system;...
  • Page 8 Warnings (for using R-290 refrigerant only) Ensure that the refrigeration system is earthed prior labels on the equipment stating the equipment con- to charging the system with refrigerant. tains flammable refrigerant. Label the system when charging is complete (if not 16.
  • Page 9: Preparations

    Preparation control panel horizontal louver blade (swing automatically) upper air filter (behind the grille) handle (both sides) upper air intake drain outlet air outlet panel lower air filter lower air intake drain outlet (only for pump heating mode) power cord buckle power cord outlet caster power plug socket...
  • Page 10: Installation

    Installation Choosing The Right Location Your installation location should meet the following requi- rements: - Make dure that you install your unit on an even surface to minimize noise and vibration. - The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
  • Page 11 Installation Part Description Quantity Part Description Quantity 1 pc 1 pc Unit Adaptor Bolt Security Bracket and 1 pc 1 set Exhaust Hose Screw 1 pc 1 pc Window Slider Adaptor Drain Hose Wall Exhaust Adaptor A Drain Hose Adaptor (only 1 pc 1 pc...
  • Page 12 Installation Note: Once the Exhaust Hose assembly and Adjustable Type 2: Wall Installation (optional) Window Slider are prepared, choose from one of the fo- 1. Cut a 125mm (4.9inch) hole into the wall for the Wall llowing installation methods. Exhaust Adaptor B. Type 1: Hung Window or Sliding Window Installation 2.
  • Page 13: Operation

    Operation NOTE: The control panel may be look like one of the followings: KP-35 CP10, KP-35 CP11 KP-35 HP10 NOTE: On some models is instead of ºF. On some models (WIRELESS light) is instead of (power light). NOTE: Some features (ION, FOLLOW ME, HEAT, WIRELESS, etc.) are optional.
  • Page 14 Operation Swing button Sleep (Eco) button Used to initiate the Auto swing feature. When Used to initiate the SLEEP/ECO operation. the operation is ON, press the SWING button can stop the louver at the desired angle. Power button Power switch on/off. Wireless button (optional) Used to initiate the Wireless function.
  • Page 15 Operation Operation Instructions initiated. And the TIMER ON indicator light illumina- ted. Press the up or down button to select the desired COOL operation Auto-on start time. - Press the “MODE” button until the “COOL” indicator - When the unit is off, press the Timer button to initiate light comes on.
  • Page 16: Maintenance

    Operation WAIT 3 MINUTES BEFORE RESUMING OPERATION Drain hose After the unit has stopped, it can not be restarted ope- adaptor √ ration in the first 3 minutes. This is to protect the unit. Drain hose Operation will automatically start after 3 minutes. adaptor POWER MANAGEMENT feature (on some models) When the ambient temperature is lower than the set-...
  • Page 17: Faults Diagnosis

    Maintenance Maintenance tips - Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mold. - Be sure to clean the air filter every 2 weeks for opti- - Turn off the appliance and unplug it. mal perfomance.
  • Page 18: Design And Compliance Notes

    Design and Compliance Notes Design Notice The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service web- site, please check for the latest version.
  • Page 19: Sociable Remark

    Sociable Remark When using this unit in the European countries, the following information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.