Summary of Contents for Kaysun KPV-140

  • Page 1 USER MANUAL FLOOR-STANDING SPLIT TYPE KPV-140 DN10 IMPORTANT Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference. This manual only describes the outdoor unit of user’s. When using the indoor unit, refer to the user’s...
  • Page 3: Table Of Contents

    CONTENTS REGULATIONS REGARDING DISPOSAL Regulations Regarding Disposal ................... 3 SAFETY PRECAUTIONS Warning ..........................5 Caution ..........................6 Prior to operation ........................... 7 Operating temperature ......................7 OPERATING INSTRUCTIONS Product overview ........................8 Unit control panel ........................ 9 Airflow direction control ......................11 Operation tips ........................
  • Page 4: Regulations Regarding Disposal

    REGULATIONS REGARDING DISPOSAL The follow contents apply to the countries of Europe. DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
  • Page 5: Safety Precautions

    SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of serious injury.
  • Page 6: Caution

    SAFETY PRECAUTIONS ! CAUTION When the air filter is to be Do not clean the air Ventilate the room well conditioner with water. when used together removed, do not touch the with a stove, etc. metal parts of the unit. It may cause an injury.
  • Page 7: Prior To Operation

    SAFETY PRECAUTIONS Prior to operation 1. Contact an installation specialist for installation. 2. Make sure the unit is grounded efficiently. 3. Do not use a damaged or non-standard power cord. 4. Do not share the same outlet with other appliances. 5.
  • Page 8: Product Overview

    Product Overview Outdoor unit Indoor unit Drain pipe, vent pipe Air outlet Connection cable Operation panel Connection pipe Horizontal airflow control louver Refrigerant pipe port Vertical airflow control louver Air outlet Remote controller holder (on some models) Air inlet (2 sides) NOTE All the pictures in this manual are for explanation purpose only.
  • Page 10: Unit Control Panel

    O P E R A T I N G I N S T R U C T I O N S Unit Control Panel Room Temp /Set Temp /Set Timer display Fan speed operation display Indic a tor s Auto operation display Cooling operation display Dry operation display Heating operation display...
  • Page 11 O P E R A T I N G I N S T R U C T I O N S FAN button : This button is used to select the desired fan speed. Each time you push the in t he direction of the arrow: button, a fan speed is shifted MED (if applicable ) HIGH...
  • Page 12 O P E R A T I N G I N S T R U C T I O N S AUXILIARY FUNCTION button: Use this button to select or cancel the auxiliary feature. button to select the desired feature. Each time the Press this button, then press button is pressed, the mode is shifted in the direction of the arrow: If press...
  • Page 13: Airflow Direction Control

    O P E R A T I N G I N S T R U C T I O N S buttons to select ON/OFF timer, press the AUXILIARY FUNCTION button again to cancel. Airflow Direction Control Horizontal Airflow Direction (AUTO) The Left/Right (Horizontal Airflow) can be adjusted by using the remote control or unit control.
  • Page 14 O P E R A T I N G I N S T R U C T I O N S During this condition air conditioner will stop heating operation and start defrosting automatically. The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost buildup on the outdoor unit.
  • Page 16: Care And Maintenance

    C A R E A N D M A I N T E N A N C E Maintenance and Cleaning CAUTION: Before performing any maintenance, turn off the main power to the system. Cleaning the indoor unit: Note: Turn the system off before cleaning. Supply power must be disconnected before cleaning the indoor unit.
  • Page 17 C A R E A N D M A I N T E N A N C E CAUTION: Make sure nothing has been forgotten or fallen into the fan before installing the air inlet grille. Restart the unit after the air inlet grid is correctly installed and the loop is fastened. Before long time idleness 1.
  • Page 18: Troubleshooting Tips

    TROUBLESHOOTING TIPS Before calling for service, please review the following list of common problems and solutions. Solutions Problem Possible Cause Power failure Wait for power restoring The power supply is disconnected. Switch on the main power switch Air conditioner does not The power fuse is blown.
  • Page 19 The following displays indicate an error or problem: Number Display Problems What to do code IDU & ODU communication Contact service people malfunction E2, E3,E4 Temperature Sensor is off or short- Contact service people circuits. EEPROM malfunction Contact service people Indoor DC fan motor speed out of control Contact service people Turn off the unit, clean the air filter, and...