LIQUEFIED PETROLEUM GAS CYLINDER REQUIREMENTS

Only use cylinders with a minimum capacity of 5 kg and a maximum capacity of 15 kg. A tank of approximately 318 mm (12.5 in) in
diameter by 580 mm (22.8 in) in height shall be the maximum size LPG cylinder which can be used.
A dented or rusty LPG cylinder may be hazardous and should be checked by your supplier. Never use a cylinder with a damaged
valve. The LPG supply cylinder to be used must be constructed and marked in accordance with the specifications for LPG cylinders
that adhere to national regulations for the country of use. The gas cylinder must have a shut-off valve terminating at the valve
outlet. Storage of an outdoor cooking gas appliance indoors is permissible only if the cylinder is disconnected and removed from
the outdoor cooking gas appliance. The cylinder system must be arranged for vapour withdrawal. The cylinder must include a collar
to protect the cylinder valve. Manifold pressure: (operating) 27.9 cm (11 in) water column, (non-operating) 28.4 cm (11.2 in) water
column.
The LPG cylinder must be fitted with an overfill protection device (OPD). Remove the plastic valve cover from the LPG cylinder. Make
sure the grill gas hoses do not contact the grease pan or grill firebox when the LPG cylinder is placed into the cart.