Download Print this page

Bosch B465 Quick Start Manual page 2

Conettix universal dual path communictor
Hide thumbs Also See for B465:

Advertisement

MODULE 1
Y
X
MODULE
RELEASE
COMMUNICATION MODULE 1
ETHERNET
100BASE-T
1
LINK
USB
SYSTEM TROUBLE
TX
RX
SDI2
POWER
Device Bus
R Y G B
BATTERY
INPUTS
2
2.2 k
End of
24 VDC
Line Resistors
or
PANEL
PANEL
16.5 VAC
1 COM 2
3 COM 4
BATTERY
LINE 1
LINE 2
3
+
-
T
R
T
R
16.5VAC
NC C NO
C
NO
C
NO
12V
1
COM
2
3
COM
4
BATTERY
RELAY 1
RELAY 2
AUX COM
PNL LINE 1
PNL LINE 2
RELAY 3
+ _
10
9
8
7
6
5
4
Callout ― Description
Callout ― Description
1 ― RJ 45 Ethernet
6 ― 12V AUX/COM terminals
connection to central station
(optional output power source,
Special Application 9.9 - 13.8 V)
2 ― External Annunciator
7 ― Programmable output relays
terminal (connected to B46)
(Relay 1, Relay 2, Relay 3)
3 ― To tamper switch
8 ― Battery (7-18 Ah)
4 ― Phone Line 1/2 to control
9 ― To earth ground
panel terminals
5 ― EOL input loop
16.5 VAC or 24 VDC power
10 ―
supply input terminals
2.11 | Earth ground wiring
Connect the system to earth ground before making other
connections. Doing so prevents damage from electrostatic
discharges or other transient electrical surges. Use a
recommended earth ground reference such as a grounding
rod, or a cold water pipe. Make the connection using 14
AWG (1.8 mm) to 16 AWG (1.5 mm) wire. Refer to the B465
Installation and Operation Guide (P/N: F01U311207).
NOTICE!
The D8004 is required for any Commercial Fire
installations that use a plug-in transformer.
2.12 | Wire to the control panel
Use compatible wiring when connecting a B465 to a intrusion/
fi re control panel to establish communication. Refer to the
following graphic.
3
1
RX
RX
A A C C
B B A A T T TE
TER R Y Y
INPU
INPUT T S S
2.2 k
2.2 k
End of
End of
L L ine
ine R R e e si sis s t t o o r r s s
P P ANEL
ANEL
P P ANEL
ANEL
1 1 C C OM 2
OM 2
3 3 C C OM 4
OM 4
LINE 1
LINE 1
LINE 2
LINE 2
PNL LINE 1
PNL LINE 2
1
COM
2
3
COM
4
2
T
R
T
R
Callout ― Description
Callout ― Description
1 ― B465 module
3 ― Intrusion/Fire control panel
2 ― Phone wiring connection
2.13 | Wire to B46 (optional)
Use compatible B46 cable to connect to the B465. Refer to the
following graphic.
1
2
MODULE 1
Y
X
MODULE
RELEASE
C C OMMUNI
OMMUNIC C A A TION MODULE 1
TION MODULE 1
ETHERNET
ETHERNET
100BASE
100BASE- - T T
LINK
LINK
USB
USB
S S Y Y S S TEM T
TEM TR R OUBLE
OUBLE
3
TX
TX
RX
RX
SDI2
SDI2
POWER
POWER
D D e e vice Bus
vice Bus
R R Y Y G G B B
B B A A T T TE
TER R Y Y
INPU
INPUT T S S
2.2 k
2.2 k
End of
End of
24
24 VDC
DC
L L ine
ine R R e e si sis s t t o o r r s s
or or
P P ANEL
ANEL
P P ANEL
ANEL
16.5 VAC
16.5 VAC
BATTE
TERY
1 1 C C OM 2
OM 2
3 3 C C OM 4
OM 4
LINE 1
LINE 1
LINE 2
LINE 2
+
-
C
NO
12V
1
COM
2
3
COM
4
T
R
T
R
16.5VAC
BATTERY
NC C NO
C
NO
RELAY 1
RELAY 2
RELAY 3
AUX COM
PNL LINE 1
PNL LINE 2
Callout ― Description
Callout ― Description
1 ― B465 module
3 ― B46 wiring (P/N: F01U310747)
2 ― B46 module
3 | Confi guration
You can confi gure the B465 using USB or RPS. For information
on confi guring the B465, refer to the B465 Installation and
Operation Guide (P/N: F01U311207).
4 | LED descriptions
The B465 and B46 modules include on-board LEDs to assist
with troubleshooting issues and communication status.
For information on all LED descriptions, refer to the B465
Installation and Operation Guide (P/N: F01U311207).
5 | Certifi cations
Region
Certifi cation
US
FCC Part 15 Class B
NIST FIPS 197 AES Certifi cation (IP Communications)
California State Fire Marshall (CSFM)
UL 365 – Police Station Connected Burglar Alarm Units and
Systems
UL 609 – Local Burglar Alarm Units and Systems
UL 864 – Control Units and Accessories for Fire Alarm Systems
UL 985 – Household Fire Warning System Units
UL 1023 – Household Burglar Alarm System Units
UL 1076 – Proprietary Burglar Alarm Units and Systems
UL 1610 – Central Station Burglar Alarm Units
Canada
CAN/ULC S303 – Local Burglar Alarm Units and Systems
CAN/ULC S304 – Signal Receiving Centre and Premise Alarm
Control Units
ULC - S545 – Residential Fire Warning System Control Units
ULC – S559 – Fire Signal Receiving Centres and Systems
ULC – ORD C1023 – Household Burglar Alarm System Units
ULC – ORD C1076 – Proprietary Burglar Alarm Units and Systems
ICES – 003 – Digital Apparatus
6 | Specifi cations
Dimensions
79 mm x 128 mm x 38 mm (3.11 in x 5.03 in x 1.50 in)
Voltage output
12 VDC nominal (Special application)
(operating)
Standby battery
*Battery input: B465: Idle 150 mA; Alarm 230 mA
current
Alarm: B465 with B440/B441/B442/B443/B444 = 180 mA
requirements
24 VDC input
*24 VDC input: B465: Idle 120 mA; Alarm 160 mA
current
requirements
USB cable
USB cable (Type A to A male-to-male) - not supplied.
Use a Bosch supported cable such as the B99 cable
(F01U278853)
Compatible
D1640, 120 VAC input, 16.5 VAC, 40 VA output Class 2
transformers
plug-in
D1640-CA 120 VAC input, 16.5 VAC, 40 VA output Class
2 plug-in
D1640-120WI, 120 VAC input, 16.5 VAC, 40 VA output
Class 2 wire-in
Compatible
Modem II, Modem IIe, Modem IIIa
2
digital dialer
Contact ID
formats
Pulse 3/1, Pulse 4/2
SIA (SIA8, SIA20)
Compatible
D6600/D6100IPv6/D6100i
receivers
Compatible
B10/B10R Medium Control Panel Enclosure
enclosures
B11/B11R Small Control Panel Enclosure
D8103 Enclosure
Compatible
B46 module (must use supporting B46 cable to connect
module
to the B465)
Relative
Up to 93% non-condensing
humidity
Temperature
0° to +49° C (+32° to 120° F)
(operating)
*Refer to the Standby battery requirements and calculations section in the
B465 Installation and Operation Guide for the current draw requirements of
other system components
ES - Visite www.boschsecurity.com para obtener documentación en este
idioma.
FR - Accédez à l'adresse www.boschsecurity.com pour obtenir la documenta-
tion dans cette langue.
BT - Acesse http://la.boschsecurity.com/pt para obter a documentação neste
idioma.
Copyright
Use the serial number located on the product label and refer to the Bosch Security
Systems, Inc. website at http://www.boschsecurity.com/datecodes/.
Trademarks
All hardware and software product names used in this document are likely to be registered
trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security
Systems, Inc. website at http://www.boschsecurity.com/datecodes/.
Conettix Universal Dual Path
Communictor
B465
en Quick Start Guide
Bosch Security Systems, Inc.
Bosch Sicherheitssysteme GmbH
130 Perinton Parkway
Robert-Bosch-Ring 5
Fairport, NY 14450
85630 Grasbrunn
USA
Germany
www.boschsecurity.com
© 2017 Bosch Security Systems, Inc.
F.01U.311.091 | 06 | 2017.08

Advertisement

loading