CONFig:TERMinal ?
Returns the current terminal mode
DEPRECATED COMMANDS – Provided for backwards compatibility, we strongly suggest you use the
'Signal' and 'Source' commands instead.
REGister:READ [0xAA]
Returns the value of the register with address [0xAA]. [0xAA] should be in hex format and
preceded by the suffix "0x". e.g. "0x6D". The value is returned in the same form as the
address.
REGister:DUMP [0xA1] [0xA2]
Returns the value of each register in a range, starting at the first register address, up to the
second. *0xA1+ and *0xA2+ should be in hex format and preceded by the suffix "0x". Each
data value will be returned on a new line.
REGister:WRITe [0xAA] [0xDD]
Writes the byte [0xDD] to register [0xAA], both [0xDD] and [0xAA] should be in hex format
and preceded by the suffix "0x". The command returns "OK" or "FAIL".
MEASure:VOLTage [3v3in?|3v3out?|5vin?|5vout?|12vin?|12vout?]
Returns the voltage on the specified rail in mV. Vin refers to the upstream or host side
of the card, and Vout refers to the switched, drive side. Values are returned in the form
"3300mV".
MEAS:VOLTage:SELF [5v?]
Returns the self test voltages. These are measurements of voltage rails required for
correct operation of the module. The values are returned in the form "5000mV"
SOURce:[1-6|ALL]:SETup [#1]
Sets up the source in a single command. All parameters are positive decimal numbers:
#1 = Initial delay (mS)
Revision 1.0
Torridon HS Lite Drive Control Module - Technical Manual
©Quarch Technology
Page 20 of 28