Default Startup State - Quarch Technology Torridon HS Technical Manual

Lite cable pull module for use with: qtl1301 - torridon hs lite drive control module using quarch firmware version 3.5 and above
Table of Contents

Advertisement

Default Startup State

On power up or reset, the control modules enter a default state. To make the module as easy to use
as possible, the default state is a 'standard' hot-swap scenario with preset source and signal settings
such that the "run:power up" command will immediately power up the drive without needing any
initial setup.
The default hot-swap scenario will connect pre-charge then power then pins, each step with a 25mS
delay. All sources are enabled.
Source
Source
Number
Enabled
1
YES
2
YES
3
YES
4
YES
5
YES
6
YES
Signal
SPECIAL1
3V3_CHARGE, 5V_CHARGE, 12V_CHARGE
3V3_POWER, 5V_POWER, 12V_POWER
PRI_OUT_PL, PRI_OUT_MN, PRI_IN_PL,
PRI_IN_MN, SEC_OUT_PL, SEC_OUT_MN,
SEC_IN_PL, SEC_IN_MN, SEC_OUT_PL,
SEC_OUT_MN
Hot-Swap State:
Drive is in the 'pulled' state, waiting for a "RUN:POWer UP" command to attach it.
Revision 1.0
Torridon HS Lite Drive Control Module - Technical Manual
Initial
Delay
0mS
25mS
50mS
0mS
0mS
0mS
©Quarch Technology
Assigned Source
Source 1
Source 2
Source 3
Source 3