S7 Server Manual
Last updated: 2/1/2016
Page 8 of 12
5 Server Configuration
5.1 Pool Setting
You can configure your server through ' Configuration->General Settings'.
Pool URL- Enter the URL of your desired pool in this column.
Worker- This is your worker ID on the selected pool.
Password- This is the password for your selected worker.
Comment:
4.1.1 The S7 server can be set up with three mining pools, with decreasing priority from the
first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if
all higher priority pools have gone offline.
4.1.2 When 'Stop running when temperature is over 80℃' is checked, the server will stop
running when the temperature exceeds 80℃ to protect the server. If it's unchecked, the server
will still run even in high temperature.
4.1.3 When "Customize the fan speed percentage" is checked, the fan speed can be controlled
by customer. If it's unchecked, the fan speed will depend on the temperature of the hash boards.
Click 'Save & Apply' to save and restart server.
5.2 Frequency Modification
You are able to modify the frequency value through 'Configuration->Advanced Settings'. The
default frequency for the S7 Server is 600M.
Page 8 / 12