4.8 Optional Filter/Reactor

Figure 4-2 shows the connections for installing an optional Line Filter and AC Line Reactor.
Control Rating
Catalog
No.
HP
Input Amps
VS1SD
2A3
1
3.2
2A4
2
4.2
2A7
3
6.8
2A10
5
9.6
2A15
7.5
15.2
2A22
10
2A28
15
2A42
20
2A54
25
2A68
30
2A80
40
2A104
50
104
2A130
60
130
* Requires custom drive for CUL application using fast fuses.
Note: Wire sizes based on 75
** Drive controller and Overcurrent Protection must be integrated within same overall assembly.
4-4 Power Wiring
Figure 4-2 Filter and Reactor Connections
L1
Filter
AC
L2
Line
L3
PE
Line
Table 4-1 240VAC Three Phase Wire Size and Protective Devices
Fast Acting (UL) Fast Acting (CUL)
9
12
15
25
35
22
40
28
70
42
80
54
100
68
125
80
150
175
200
0
C copper wire. Fuses based on 40
L1
L1
L2
L2
Reactor
L3
L3
PE
PE
Load
Input Fuse (Amps)
Time
Delay
9
6
12
9
15
12
25
20
35
30
40
35
70
60
80
70
*100
*125
*150
175
150
200
175
0
C ambient, max continuous output and no harmonic current.
Control
Semiconductor (CUL)
A50QS100-4 **
A50QS125-4 **
A50QS150-4 **
Wire Gauge
AWG
mm
2
14
2.5
14
2.5
14
2.5
14
2.5
12
4
10
6
8
10
6
16
4
25
4
25
4
25
2
50
2/0
70
MN766

Hide quick links: