Maintenance

Changing the Battery
1. Remove screw on rear of unit near the middle with a #1 Philips
head screwdriver.
2. Remove battery and disconnect from battery snaps.
3. Attach a new 9 volt alkaline battery to the battery snaps and
return to battery compartment.
4. Place battery cover in slot and rotate shut. Fasten shut with
screw removed. Do not over tighten!
Replacing the Fuse in the 40A In-Line Adapter Module
The 40A In-Line Adapter Module contains a fuse used to protect
Fault Trapper cabling and circuitry.
Replace fuse with same type and rating! The fuse is a special type
capable of interrupting high current circuits.
1. Remove four case screws using
a T-15 Torx® driver and open the
case.
2. Remove Fuse cover and fuse.
Replacement fuse is Littelfuse®
p/n 0215.250, 5x20 mm, time-lag,
0.25Amp, 250VAC.
3. Replace fuse cover, reassemble
case, replace 4 screws and tighten.
Warning! Remove any cables attached to the
Fault Trapper™ before opening any battery
compartment!
Warning! To avoid electrical shock, remove
any cables attached to the 40A In-Line Adapter
Module before opening the case!
Warning! Never operate 40A In-Line Adapter
Module without the connector side panel being
installed! After servicing the fuse, verify safe state
of case and operation of unit.