Daikin FTXV25AV1B Service Manual page 48

Inverter pair wall mounted type ftxv-ab series
Hide thumbs Also See for FTXV25AV1B:
Table of Contents

Advertisement

Troubleshooting
Error Code List
Display Method of Indoor Unit
Malfunction
No.
Name
High
pressure
1
protection of
system
Antifreezing
2
protection
Refrigerant
3
leakage
protection
High
discharge
4
temperature
protection of
compressor
Overcurrent
5
protection
Communi-
6
cation
Malfunction
High
temperature
7
resistant
protection
EEPROM
8
malfunction
Limit/
decrease
frequency
9
due to high
temperature
of module
Malfunction
10
protection of
jumper cap
40
Indicator Display (during
blinking, ON 0.5s and OFF
0.5s)
Operation
Cool
Heating
Indicator
Indicator
Indicator
OFF 3s
and blink
once
OFF 3S
and blink
twice
OFF 3S
and blink
4 times
OFF 3S
and blink
5
times
OFF 3S
and blink
6
times
OFF 3S
and blink
8
times
OFF 3S
and blink
15 times
OFF 3S
OFF 3S
and blink
and blink
6 times
6 times
OFF 3S
and blink
15 times
Display Method of Outdoor
Unit
Indicator has 3 kinds of
display status and during
blinking, ON 0.5s and OFF
0.5s
Yellow
Red
Green
Indicator
Indicator
Indicator
During cooling and drying
operation, except indoor
fan operates, all loads stop
operation.
During heating operation, the
complete unit stops.
During cooling and drying
OFF 1S
operation, compressor and
and blink
outdoor fan stop while indoor
3 times
fan operates.
OFF 1S
The Dual-8 Code Display will
and
show F0 and the complete unit
blink
stops.
9 times
During cooling and drying
OFF 1S
operation, compressor and
and blink
outdoor fan stop while indoor
7 times
fan operates. During heating
operation, all loads stop.
During cooling and drying
OFF 1S
operation, compressor and
and blink
outdoor fan stop while indoor
5 times
fan operates. During heating
operation, all loads stop.
During cooling operation,
compressor stops while
Always
indoor fan motor operates.
ON
During heating operation, the
complete unit stops.
During cooling operation:
OFF 1S
compressor will stop while
and blink
indoor fan will operate.
6 times
During heating operation, the
complete unit stops.
During cooling and drying
OFF 1S
operation, compressor will stop
and blink
while indoor fan will operate;
11 times
During heating operation, the
complete unit will stop
All loads operate normally,
while
operation frequency for
compressor is decreased
Wireless remote receiver and
button are effective, but can
not dispose the related
command
A/C status
Possible Causes
Possible reasons:
1. Refrigerant was superabundant;
2. Poor heat exchange (including
and bad radiating environment );
Ambient temperature is too high.
1. Poor air-return in indoor unit;
2. Fan speed is abnormal;
3. Evaporator is dirty.
1. Refrigerant leakage;
2. Indoor evaporator temperature
sensor works abnormally;
3. The unit has been plugged up
somewhere.
Please refer to the malfunction
analysis (discharge protection,
overload).
1. Supply voltage is unstable;
2. Supply voltage is too low and
load is too high;
3. Evaporator is dirty.
Refer to the corresponding
malfunction analysis.
Refer to the malfunction analysis
(overload, high temperature
resistant).
Replace outdoor control panel AP1
Discharging after the complete unit
is de-energized for 20mins, check
whether the thermal grease on
IPM Module of outdoor control
the radiator is inserted tightly.
If its no use, please replace control
panel AP1.
1. No jumper cap insert on
mainboard.
2. Incorrect insert of jumper cap.
3. Jumper cap damaged.
4. Abnormal detecting circuit of
mainboard.
SiK011003
Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading