SRM-3020T
Lubrication
Level 1.
Parts Required:
Gear Housing
1.
Clean all loose debris from gear
case.
2.
Remove plug (A) and check level
of grease.
3.
Add grease if necessary. DO
NOT over-fill.
Drive Shaft
1.
Loosen screw (B) and remove
locating screw (C). Pull gear case and shieldfrom drive shaft housing.
2.
Pull flexible cable from the drive shaft housing, wipe clean and re-coat
with 15 ml (0.5 oz.) of grease.
3.
Slide the flexible cable back in the drive housing. DO NOT get dirt on
the flex cable.
4.
Install the gear housing and shield assembly.
Nylon Line Head Disassembly Instructions
Note: For normal use, Speed Feed
necessary. However, if circumstances require disassembly,
follow these instructions.
1.
Press top of locking tabs (A) on
both sides of Speed Feed
head to release cover (B) from
eyelet carrier (C).
2.
Remove cover from eyelet
carrier.
X7502350100
© 04/2018 ECHO Inc.
Lithium Based Grease.
®
MAINTENANCE
C
B
®
head disassembly is not
C
A
A
B
39