Page 1
S H E D S Vinyl Garden Shed Vinyl Garden Shed OWNER’S MANUAL / Patent #416.091 Instructions for Assembly ‘10 Ft WoodBridge’ Size 10 Ft x 8 Ft / 3.2 m x 2.4 m (Approx.) Ver: 4.0 Customer Service Hotline (800) 483-4674 www.duramaxbp.com...
Page 2
Duramax Garden Shed Limited Fifteen Year Warranty U.S. Polymer Inc. will send a replacement part free of charge, in the event of material defects and or workmanship for a period of fifteen years from the date of purchase. This warranty is extended only to the original purchaser. A purchase receipt or other proof of date of original purchase will be required before warranty service is rendered.
Page 3
SAFETY & PRECAUTIONS Before You Begin... 1. Check your local building codes regarding footings, location, etc. 2. Select a site that allows enough working space around the shed. 3. Determine building foundation and anchor system. 4. Read and understand the Owner’s manual enclosed in the package. 5.
Page 4
SAFETY & PRECAUTIONS For your own safety, please read and follow these instructions during the shed assembly. 1. Always wear work gloves, long sleeves and eye protection during assembly of the shed. Some pieces of the shed contain sharp edges and can cause injury. 2.
Page 5
IMPORTANT Wear eye protection when using any form of power tools. Do not use voltage power tools in a wet or damp enviornment to avoid electric shock. Do not use any part of the shed as a means of personal support while attaching components during assembly. The shed must be constructed on a solid base foundation.
Page 8
A. Foundation Note : If you have DURAMAX Foundation, please follow instruction manual in that package. If not, follow below wooden platform instruction. Note DuraMax must be installed on a level wooden platform or a level concrete foundation. Wooden Platform (Not Included) The following are the list of lumber and sizes you will need.
Page 9
B. Base Frame Parts Needed: Note 1. It is important that these instructions Code are followed step by step. 2. All parts are clearly marked and care B1LA should be taken to use the correct one. B1RA 3. Don’t install under windy conditions. B3LA 4.
Page 10
C. Wall & Columns Parts Needed: Code CDLA CDRA CB1A CB2A CB3XA CB4A 1. All parts are clearly marked and Note care should be taken to use the correct one. 2. Set the Torque limit of your Screw drill to #3 or #4 to ensure the screws do not strip the metal reinforcements.
Page 11
Note Check the stamped label on top of all panels inside. CDRA CDRA Front B1RA Fig.1 B1RA Fig.1 Fig.2 2&3 B1RA Fig.3 Note Do not tighten the screw. Leave it loose Fig.1...
Page 18
Fig.1 CB3XA CB3XA Fig.2 Fig.3 Fig.1 B1LA B1LA B1LA 2&3 Fig.2 Fig.3 Note Do not tighten the screw. Leave it loose Fig.1...
Page 19
CB3XA CB3XA Fig.1 CDLA B1LA CDLA CDLA Fig.1 Fig.2 B1LA CDLA CB1A CDLA CB1A 1&3 Fig.1 Fig.2 CB1A CB1A CB3XA Fig.3 Note After completing the center band assembly, fully tighten the four center band fittings (FCB) to the corner column (CCA).
Page 33
D. Roof Panels Note Insert roof plugs into Facia Panel only as indicated. Parts Needed: Code RS14A Front Front Back Back...
Page 34
Note Note Apply silicone around the roof Use a screw driver to align the holes. plugs and the pin holes before fixing the pins. Insert roof plugs into roof panels only as indicated. Front Note Roof Panel installation by using ladder from inside at missing Panels.
Page 36
E. Door Note Apply silicone around the perimeter of the base ‘U’ channel. Seal the corners, joints and base of door column. This is optional and should be done for heavy rain areas if needed. Base ‘U’ channel Column Fig.1 Base ‘U’...
Page 37
F. Ventilation Kit Parts Needed: Code TOOLS YOU WILL NEED Power Drill Dia 3/16” (5mm) drill bit Dia 1/2” (12.5mm) drill bit Note Optional ventilation kits can be installed on any of the wall panels. However, we recomend mounting them on the top of the shed’s back wall. Outside Outside...
Page 38
High wind area installation instructions Note: To ensure that your shed withstands high winds, you will need the following reinforcement. Parts needed (not included) CODE DESCRIPTION Dia. 4.2 x 16mm. (5/32” x 5/8”) Sheet Metal Screw M6 x 40mm. (1/4” x 1 1/2”) Anchor Bolt Base ‘U’...
Page 39
Base U-channel Important Warranty Information The ‘DURAMAX’ shed has been tested and passed wind loads of up to 115 mph in a controlled laboratory environment. Natural high wind areas create wind at unpredictable speeds that are very difficult to capture accurately by location. As such we cannot guarantee the performance of the shed in these extreme situations.
Page 40
ADDITIONAL ACCESSORIES AVAILABLE These accessories are required in case of heavy snow or high wind areas. Please choose relevant accessories according to your needs. SUPER SUPPORT KIT Extra roof beams for added protection against heavy snow accumulation. For heavy snow area. ANCHOR KIT (Soil) Wire rope with twist augers for sheds installed with foundation (Wood / Metal) on soil.
Page 41
U.S. Polymers, Inc. 1057 S. Vail Ave Montebello, CA 90640, United States of America RD-4.0 2013-11-12...