SolaX Power X1-Fit-3.7C User Manual

SolaX Power X1-Fit-3.7C User Manual

X1-retro fit series
Hide thumbs Also See for X1-Fit-3.7C:

Advertisement

Description
REV.
REV.
首次发行
0.0
夏炅
2017/7/18
A 修改相对湿度参数和尺寸、AC和EPS接线端
口,增加Off Mode、参数单位,修正语法错误。
0.0
夏炅
2017/7/27
B 修改技术要求:装订方式
0.0
夏炅
2017/8/1
C 增加发电机控制接口内容
0.0
夏炅
2017/8/3
修改BMS&Meter接线步骤和结构图;增加公司新名称;修改DSP/ARM烧
录顺序DSP升级路径等其他信息;修改LCD Operation
0.1
夏炅
2017/10/12
描述
X1-Retro Fit Series说明书
浙江艾罗电源有限公司
SolaX Power Co.,Ltd.
料号
614.00204.01
单位
页次
Description
技术要求:
1.封面封底157g铜版纸覆哑膜彩打,内部纸80g双胶纸黑白印刷,正反打印
2.装订方式:页码大于60需用胶装
3.未注尺寸公差按 +- 1.5mm
4.图面、字体印刷清晰、无偏移/无毛边、不起边、油墨不脱落
5.字体颜色为PANTONE Black C,无边框,底色为白色
6.符合RoHS要求
Q-OP-SC-01-02 V1.0
285.00 mm
设计
描述
X1-Retro Fit Series说明书
审核
NA
材料
核准
料号
614.00204.01
浙江艾罗电源有限公司
单位
页次
炅 2017/7/18
朱娴红 2017/7/18
朱娴红 2017/7/18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X1-Fit-3.7C and is the answer not in the manual?

Questions and answers

Summary of Contents for SolaX Power X1-Fit-3.7C

  • Page 1 设计 2.装订方式:页码大于60需用胶装 描述 X1-Retro Fit Series说明书 3.未注尺寸公差按 +- 1.5mm 审核 朱娴红 2017/7/18 4.图面、字体印刷清晰、无偏移/无毛边、不起边、油墨不脱落 描述 X1-Retro Fit Series说明书 浙江艾罗电源有限公司 材料 核准 朱娴红 2017/7/18 5.字体颜色为PANTONE Black C,无边框,底色为白色 SolaX Power Co.,Ltd. 料号 料号 614.00204.01 614.00204.01 6.符合RoHS要求 浙江艾罗电源有限公司 Q-OP-SC-01-02 V1.0 单位 页次 单位 页次...
  • Page 2 Solax Power Network Technology(Zhe jiang) Co,. Ltd. Copyright Declaration The copyright of this manual belongs to Solax Power Network Technology(Zhe jiang) Co,. Ltd. (Solax Power Co,. Ltd) (SolaX Power Co.,Ltd.). Any corporation or individual should not plagiarize, partitially or fully copy (including software,etc.), and no reproduction or distribution of it in any form or by any...
  • Page 3: Table Of Contents

    Contents Contents 1 Note on this Manual 1.1 Scope of Validity 1.2 Target Group 1.3 Symbols Used 2 Safety 2.1 Important Safety Instructions 2.2 Explanation of Symbols 2.3 EC Directives 3 Introduction 3.1 Basic Features 3.2 Work Sta 3.3 Dimension 3.4 Terminals of Inverter 4 Technical Data 4.1 AC output/input ( apply to version E, I, C )
  • Page 4: Target Group

    6.10 Inverter Manipulation X1-Fit-3.7E X1-Fit-4.6E X1-Fit-5.0E X1-Fit-3.7I X1-Fit-4.6I X1-Fit-5.0I X1-Fit-3.7C X1-Fit-4.6C X1-Fit-5.0C 7. Firmware Upgrading Note: “3.7” means 3.7kW. “E” means “EPS function” will be available with an external changeover 8. Setting device installed. 8.1 Control Panel “I”...
  • Page 5: Safety

    Safety Safety 2 Safety Prior to the application, please read this section carefully to ensure correct and safe application. Please keep the user manual properly. Accesories only together with the inverter shipment are recommanded here. 2.1 Important Safety Instructions Otherwise may result in a risk of fire, electric shock, or injury to person. Make sure that existing wiring is in good condition and that wire is not Danger! undersized.
  • Page 6 Safety Safety For United Kingdom To protect the AC system, surge suppression devices (SPD type2) should be • The installation that connects the equipment to the supply terminals shall fitted at the main incoming point of AC supply (at the consumer’s cutout), comply with the requirements of BS 7671.
  • Page 7: Explanation Of Symbols

    Safety Safety 2.2 Explanation of Symbols The inverter can not be disposed together with the household waste. This section gives an explanation of all the symbols shown on the inverter and Disposal information can be found in the enclosed documentation. on the type label.
  • Page 8: Introduction

    Introduction Introduction 3. Introduction I Version applies to the wiring rules that requires Neutral line of alternative supply must NOT be isolated or switched (applies to wiring rules AS/NZS_3000:2012 for Australia and New Zealand). 3.1 Basic features Retro Fit Series is a high-quality inverter which can store energy into battery. The inverter can be used to optimize self consumption, store in the battery for future use or feed-in to public grid.
  • Page 9: Dimension

    Introduction Introduction the power is not enough,battery will discharge 3.2 Work Modes for local loads firstly, and grid will supply power when the battery capacity and power X1-Retro Fit Series inverter provides multiple work modes based on different generation is not enough. requirements.
  • Page 10: Terminals Of Inverter

    3.4 Terminals of PV inverter 4. Technical Data 4.1 AC output/input ( apply to version E, I,C ) X1-Fit-3.7E X1-Fit-4.6E X1-Fit-5.0E X1-Fit-3.7I X1-Fit-4.6I X1-Fit-5.0I Model X1-Fit-3.7C X1-Fit-4.6C X1-Fit-5.0C AC output 3680 4600 4999 Norminal AC power[VA] 3680 4600 4999 Max. apparent AC power[VA]...
  • Page 11: Efficiency, Safety And Protection ( Apply To Version E, I,C )

    X1-Fit-3.7E X1-Fit-4.6E X1-Fit-5.0E X1-Fit-3.7E X1-Fit-4.6E X1-Fit-5.0E X1-Fit-3.7I X1-Fit-4.6I X1-Fit-5.0I Model X1-Fit-3.7I X1-Fit-4.6I X1-Fit-5.0I Model X1-Fit-3.7C X1-Fit-4.6C X1-Fit-5.0C X1-Fit-3.7C X1-Fit-4.6C X1-Fit-5.0C Max. Battery charge efficiency Dimension [W/H/D](mm) 476*464*180 95.60% 95.60% 95.60% AC to BAT )(@full load) Dimension of packing [W/H/D](mm) 600*540*350 Max.
  • Page 12: Installation

    Installation Installation 5. Installation Object Description gasket( for using thin cable to connect on the AC port) Grounding nut Set screw( for mounting) 5.1 Check for Physical Damage User manual Make sure the inverter is intact during transportation. If there is any visible Warranty card damage, such as cracks, please contact your dealer immediately.
  • Page 13 Installation Installation Ø Space Requirement 375.0 mm 300mm Table Available Space Size Position Min.size 300mm 300mm Left 300mm Right 300mm 300mm Bottom 300mm Front 300mm Step 1 300mm Ø Mounting Steps Tools required for installation. Installation tools : crimping pliers for binding post and RJ 45, screwdriver, Step 2 manual wrench and Step 1: Screw the wall bracket on the wall...
  • Page 14: Electrical Connection

    Table 4 Cable and Micro-breaker recommended X1-Fit-3.7E X1-Fit-4.6E X1-Fit-5.0E Model X1-Fit-3.7I X1-Fit-4.6I X1-Fit-5.0I X1-Fit-3.7C X1-Fit-4.6C X1-Fit-5.0C Step3. Cable Size: Refer to Tabel 4(page 24) E Version & C Version Cable 4-5mm² 5-6mm²...
  • Page 15: Eps Connection( Apply To I Version And E Version)

    Electrical Connection Electrical Connection 6.2 EPS Connection( apply to I Version and E Version only) E Version Manual Required for Changeover Switch X1-Retro Fit series inverter has On and Off grid function, the inverter will deliver E Version wired by manufactor output power through AC port when the grid is on, and it will deliver output required for installation RCMB...
  • Page 16 ( W ) load Table 5 Cable and Micro-breaker recommended Incandescent Incandescent lamp lamp X1-Fit-3.7E X1-Fit-4.6E X1-Fit-5.0E Model X1-Fit-3.7I X1-Fit-4.6I X1-Fit-5.0I X1-Fit-3.7C X1-Fit-4.6C X1-Fit-5.0C EPS Cable ≥5mm² ≥5mm² ≥5mm² EPS breaker Capacitive 80VA 60VA X 1.5 load ( W ) ( W ) Step2.
  • Page 17: Battery Connection

    X1-Fit-5.0E Model X1-Fit-3.7I X1-Fit-5.0I X1-Fit-4.6I Step4. Tighten the screw connection(tighten torque:2.0Nm) X1-Fit-3.7C X1-Fit-4.6C X1-Fit-5.0C Nominal voltage of DC breaker should be larger than maximum Step5. Plug the PV conntector into the corresponding PV connector on inverter. Voltage voltage of battery.
  • Page 18: Earth Connection

    Electrical Connection Electrical Connection Ø Communication Connection Steps: 6.4 Earth Connection Step1. Disassemble the BMS/Meter cable gland. Users can addtionally earth the inverter to the enclosure of a second earthing or equipotential bonding if it is required by local safety. This prevents electric shock Step2.
  • Page 19: Meter Connection

    Electrical Connection Electrical Connection Ø Meter Connection Steps: 6.5 Meter Connection Please refer to BMS connection steps (page32) for Meter connection. Please kindly Meter is used for monitoring the power usage for entire house, at the meantime,  noted the PIN definition and port position will be slightly different. inverter will also need the data from Meter to achieve the Export Control Function. Step1. Disassemble the BMS/Meter cable gland. Note!...
  • Page 20: Lan Connection

    Electrical Connection Electrical Connection 6.6 LAN Connection 6.7 DRM Connection LAN communication is the standard communication interface. It can transmit the DRM is provided to support several demand response modes by emitting control data between the router and inverter via the local network. signals as below.
  • Page 21: Wifi Connection(Optional)

    Electrical Connection Electrical Connection 6.8 WiFi Connection(optional) 6.9 RF Connection(optional) Inverter provides a WiFi port which can collect data from inverter and X1-Retro Fit inverter provides a RF( radio frequency) interface which control the transmit it to monitoring-website via a Pocket WiFi. switch time of a designated load via an exteral Smart Plug (purchase the product (Purchase the product from supplier if needed) from supplier if needed.) so that the load mostly consumes energy and incurs...
  • Page 22: Inverter Manipulation

    Electrical Connection Electrical Connection Ø Check the inverter: 6.10 Inverter Manipulation Ø Start inverter after checking all below steps: Step1. Check the status of indicators and LCD screen. The left indicator should be blue and the indicator screen should display the main interface. Ensure the inverter fixed well on the wall.
  • Page 23: Firmware Upgrading

    Firmware Upgrading Electrical Connection Firmware Upgrading 7. Firmware Upgrading Step2 User can upgrade inverter’s firmware via an U-disk. U-disk Ø Preparation Please ensure the inverter is steadily powered on. Inverter must keep the battery on through whole procedure of upgrading. Please prepare a PC and an U-disk.
  • Page 24: Setting

    Setting Setting 8. Setting 8.2 Menu Structure All advance setting can only be set Grid by the technician or the installer with the installer password. 8.1 Control Panel Charger Safety Power Factor Load Grid Inverter Yield Export Control On-grid EPS Yield Remote Control P(U ) Function Load Consume...
  • Page 25: Lcd Operation

    Setting Setting Ø Status 8.3 LCD Operation Grid LCD Digital Display Charger The main interface is the default interface, the inverter will automatically jump to this interface when the system started up successfully or not operated for a period of time. The information of the interface is as below.
  • Page 26 Setting Setting History ● The history function contains five items of the information: Inverter yield, EPS yield, c) EPS load consume, Meter yield and error logs. EPS will only have data when the inverter is working in EPS mode, it will show the real time data of the EPS output such as voltage, current, power, frequency.
  • Page 27 Setting Setting Ø Setting Safety d) Meter Yield (d-1-1) The Meter Yield contains four items: FeedInToday, FeedInTotal, ConsumeToday Power Factor (d-1-2) and ConsumeTotal. (d-1) Grid (d-1-3) On-grid Meter Yield >FeedInToday: Export Control (d-1-4) 0.0KWH (d-1-5) Remote Control Date Time P(U ) Function (d-1-6) e) Error Logs The Error logs record the lastest six error messages happened.
  • Page 28 Setting Setting a) Date Time Safety (d-1-1) This interface is for user to set the system date and time. Power Factor (d-1-2) Date time Grid (d-1-3) 2013 ->06 <-06 10:19 (d-1) Export Control (d-1-4) On-grid (d-1-5) Remote Control b) Language This inverter provides several languages for customer to select.
  • Page 29 Setting Setting Reactive power control, Reactive standard curve cos φ = f(P) d-1-3) Grid The enduser do not need to set the grid parameters. All default value has set on For VDE ARN 4105, curve cos φ = f(P) should refer to curve A. default value of setting is as factory according to safety rules.
  • Page 30 Setting Setting d-1-8)Self Test (applies to CEI 0-21 only) d-1-5) Remote Control user can test operating status of inverter by choosing ”Start Test” . It will turn back Remote control function allows external control device to make the inverters to the Home page automatically and shows ”SelfTesting... ” . 60 seconds later, it will remote cluster control through LAN port on the inverter .
  • Page 31 Setting Setting (d-2) Charger (d-2-1) NOTE! Battery • When you want to use the EPS function, the setting of the discharge (d-2-2) cut voltage need to be higher than the Battery backup discharge Volt. • The Battery backup discharge Volt is the min Voltage of the battery. d-2-1) Charger Here the user can set the parameters of charger on this page, the inverter is only compatible with lithium battery.
  • Page 32 Setting Setting d-3-4) Reset Load (d-4) Work Mode (d-4-1) User can reset the specific load’s energy if the inverter is installed with a User-define (d-4-2) Relay Control smart plug. Reset Load New Password (d-4-3) Reset Load 1 >No< d-4-1) Work mode There are 5 work modes for choice.
  • Page 33 Setting Setting Parameter Comment Inverter SN Charger start time1 The start time of the rst charger period. Register1 SN Charger end time1 The end time of the rst charger period. Charger start time2 The start time of the second charger period. Register2 SN The end time of the second charger period.
  • Page 34: Troubleshooting

    Troubleshooting Troubleshooting 9. Troubleshooting The grid voltage is out of range for the last 10 Minutes. • The system will back to normal if the grid is back. 9.1 Trouble shooting AC10M Volt Fault • Or seek for help from us. This section contains information and procedures for solving possible problems DCI over current protection Fault.
  • Page 35 Troubleshooting Troubleshooting BMS Communication Lost Battery Fault-over-temperature fault BMS_TemHigh • Please contact battery suppiler. • Check if the BMS cable is loose or broken. BMS Lost • Or seek help from us, if can not go back to normal state. Battery Fault-under-temperature fault BMS_TemLow •...
  • Page 36: Routine Maintenance

    Troubleshooting Decommissioning 10. Decommissioning 9.2 Routine maintenance Inverters do not need any mainteinance or correction in most condition,but if 10.1 Remove the Inverter the inverter often loses power due to overheating,this can be the following reason: Disconnect the inverter from AC output. ●...