Maximum combined USB device power consumption is 500 mA at 5 V.
Section 3.2

Installing/Removing Line Modules

Upon installing a new line module in the device, all features associated with the module are available in
RUGGEDCOM ROX II. For more information, refer to the RUGGEDCOM ROX II User Guide for the RUGGEDCOM
RX1501.
Once a line module is removed, all the features associated with the module are hidden or disabled in RUGGEDCOM
ROX II.
CAUTION!
Electrical hazard – risk of power failure. Do not install more than two RUGGEDCOM APE modules.
Installing more than two of this type of module can lead to power fluctuations and irregular shut
downs.
IMPORTANT!
Only one WAN line module is supported per chassis.
Installing/Removing Line Modules
Specifications
Operating System: Windows®
Embedded Standard 7
Processor: Intel Atom E660T 1.3
GHz, 512 KB L2 Cache
RAM: 2 GB DDR2, 800 MHz, 32-
bit
Disk: 16 GB SATA, Solid State
Networking: Realtek RTL8111,
RJ45 Gigabit Ethernet Interface
a
USB: 2 x USB 2.0
Video: Intel 4108 Graphics
Processor, DVI-D
Specifications
Operating System: Check Point
GAiA™ OS
Processor: Intel Atom E660T 1.3
GHz, 512 KB L2 Cache
RAM: 2 GB DDR2, 800 MHz, 32-
bit
Disk: 16 GB SATA, Solid State
Networking: Realtek RTL8111,
RJ45 Gigabit Ethernet Interface
a
USB: 2 x USB 2.0
Video: Intel 4108 Graphics
Processor, DVI-D
Chapter 3
Modules
Article Numbers
6GK60150AL200GE0 (Standard)
6GK60150AL200GE1 (Conformal
Coated)
Article Numbers
6GK60150AL200GF0 (Standard)
6GK60150AL200GF1 (Conformal
Coated)