Summary of Contents for Comelit 4682HD

  • Page 1 TECHNICAL MANUAL Audio/video module for ViP system Passion.Technology.Design. Art. 4682HD...
  • Page 2: Table Of Contents

    • any purpose other than the intended use, • failure to observe the indications and warnings contained in this Manual / Instruction sheet. Comelit Group S.p.A. reserves the right to change the information provided in this Manual / Instruction sheet at any time and without prior notice.
  • Page 3: Description

    Description The 4682HD colour audio-video module is compatible with ViP door entry monitor systems. It can be installed in Ikall, Ikall Metal, Vandalcom and Roma series external units and can be finished with additional modules to meet all system requirements.
  • Page 4 1. Programming DIP-switch for button module indexing 6. Indicator LED: call sent Device reset 7. Speaker. 2. Power supply indicator LED 8. Microphone. 3. PR switch for input/output programming 9. Indicator LED: system busy in programming mode 10. Indicator LED: sound activated normal operation 11.
  • Page 5: Technical Characteristics

    Technical characteristics MAIN FEATURES Audio/video systems Induction loop module output Camera Colour Diagonal viewing angle 125° Video encoding H.264 Camera sensor 1/3" CMOS Signal/noise ratio (dB) Camera positioning Power supply voltage 30 - 57 / PoE Consumption in standby 3.0 W Consumption during call 5.5 W Consumption with audio active...
  • Page 6: External Unit Installation

    External unit installation 40-45 cm 125° MAX Connect the module support frame to earth The camera must not be installed in front of light sources, or in places where the filmed subject is against the light. In dim environments, we recommend additional lighting is provided. CAUTION The wires must be long...
  • Page 7: Connections

    BROWN & WHITE BROWN BLUE & WHITE BLUE ORANGE WHITE ORANGE GREEN WHITE GREEN 4682HD NC NO Local lock-release button For further information on module connection, please refer to Module Connection Connection with additional power supply (Art. 1595) √ The additional power supply is necessary when you want to connect additional modules which require a power level greater...
  • Page 8: Variants

    On C. NO. contacts On C. NC. contacts contact In case of replacement of a module previously installed, with the Art. 4682HD: f remove the existing terminal block and replace it with the terminal block supplied with item 4682HD 4682HD 4682HC NC NO f connect the 4682HD module as shown in the wiring diagram below.
  • Page 9: Module Connection

    Module Connection On systems with Art. 4682HD and Art. 1595, the MAXIMUM power available for the additional external unit modules is 10.5W. On systems with Art. 4682HD and Art. 1440+1441, the MAXIMUM power available for the additional external unit modules is 5W.
  • Page 10: Connection Of Ikall Modules

    1441 1440 BROWN & WHITE BROWN BLUE & WHITE BLUE ORANGE WHITE ORANGE GREEN WHITE GREEN 4682HD NC NO MAX 12 MAX. 20 modules using Connection with additional power supply (Art. 1595) Connection of Art. 3360B, 3360BM 1441 1440 BROWN & WHITE BROWN BLUE &...
  • Page 11: Connection Of Vandalcom Modules

    BROWN & WHITE BROWN BLUE & WHITE BLUE ORANGE WHITE ORANGE GREEN WHITE GREEN NC NO N°1 N°2 N°10 MAX 10 4682HD+3268S 3064S 3064S 3064S 3064S BLACK MAX 10 1172B 1172B 1172B 1172B Use the cable supplied with Art. 3268S MAX.
  • Page 12: Connection Of Art. 3070S, 3072S

    1440 BROWN & WHITE BROWN BLUE & WHITE BLUE ORANGE WHITE ORANGE GREEN WHITE GREEN NC NO 4682HD 3070S 3072S "V-" BLUE "S" YELLOW "V+" BROWN 2E7T000696 Use the cable 2E7T000696 supplied with Art. 3070S and Art. 3072S Modules for Single-plate external unit Connection of Art. 3063D with additional power supply...
  • Page 13: Simplekey Modules

    Simplekey modules Connection of readers Art. SK9000I, Art. SK9001I 1441 1440 ORANGE WHITE ORANGE GREEN WHITE GREEN 1595 120-230 V 4682HD C NO NC NO SK9000I SK9001I MAX 20 12/24V AC/DC MAX. 20 modules...
  • Page 14: Programming

    Programming Assigning an index number to the “additional button modules” The following procedure is used to assign an index number to each “additional button module”. The module index must then be used with the ViP Manager software to complete module button programming (see manual for ViP Manager software).
  • Page 15: Addressing Table

    Addressing table Dip switch Dip switch Dip switch Dip switch Dip switch Dip switch Dip switch Dip switch Code Code Code Code Code Code Code Code 1,2,3,4,5 1,3,4,5,6 1,2,4,5,7 1,4,5,6,7 1,2,3,5,8 1,3,5,6,8 1,2,5,7,8 2,3,4,5,6 3,4,5,7 2,4,5,6,7 4,5,8 2,3,5,6,8 3,5,7,8 1,2,3,4,5.6 1,3,4,5,7 1,2,4,5,6.7 1,4,5,8...
  • Page 16: Device Reset

    Device reset The reset procedure restores the factory settings of the external units, deleting all settings implemented by the installer. SLOW BLINK LED ON 10'' FAST BLINK...
  • Page 17: Connection Distances

    Connection distances 6802W 6722W 6802B 6742W 6842W MAX 150m MAX 100m (10Mb) (100Mb) 1440 (100Mb) (10Mb) 1441 1441B MAX 150m MAX 150m 4682HD If Art.4682HD is powered directly from third-party standard POE switches, the maximum distance is reduced to 100 m.
  • Page 18 C E R T I F I E D M A N A G E M E N T S Y S T E M S w w w . c o m e l i t g r o u p . c o m Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy...

Table of Contents

Save PDF