Download Print this page

Installation Instructions - Vulcan-Hart V2BG24 Manual

V series heavy duty gas ranges

Advertisement

INSTALLATION INSTRUCTIONS

1.
A properly sized gas pressure regulator suitable for battery
or single unit application must be furnished and installed.
Natural gas 6.0" W.C., propane gas 10 W.C.
2.
An adequate ventilation system is required for commercial
cooking equipment. Information may be obtained by
writing to the National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269, www.NFPA.org.
When writing, refer to NFPA No. 96.
3.
These units are manufactured for installation in
accordance with ANSZ223.1A (latest edition), National
Fuel Gas Code. Copies may be obtained from The
American Gas Association, 400 N Capitol St. NW,
Washington, DC 20001, www.AGA.org.
4.
Clearances
Combustible
Non-combustible
TOP
CONFIGURATION
NUMBER
V2BG24
V2BG24B
V2BG24S
V2BG24C
P.O. Box 696
Louisville, KY 40201
n
F38229 (10/09)
V
V S
ULCAN
ER IE S
2-BURNER / 24" INCH MANUAL GRIDDLE
Rear
Sides
10"
10"
0"
0"
MODEL
2-Burners / 24" Wide Manual Griddle / Modular
2-Burners / 24" Wide Manual Griddle / Cabinet Base
2-Burners / 24" Wide Manual Griddle / Standard Oven Base
2-Burners / 24" Wide Manual Griddle / Convection Oven Base
Toll-free: 1-800-814-2028
n
H
D
EAV Y
UTY
HEAVY DUTY GAS RANGE
36" WIDE GAS RANGE
5.
For proper combustion, install equipment on adjustable
legs or casters. On curb or platform, allow 3-
overhand. Toe base with leveling bolts are required for
curb installation. Specify when ordering.
6.
Cannot be batteried with GH series equipment.
7.
This appliance is manufactured for commercial
installation only and is not intended for home use.
NOTE: In line with its policy to continually improve its
product, Vulcan reserves the right to change materials
and specifications without notice.
Specify type of gas when ordering. Specify altitude when
above 2,000 feet.
DESCRIPTION
Vulcan & Wolf Range
a division of ITW Food Equipment Group LLC
Local:
502-778-2791
n
R
ANGES
TOTAL INPUT
SHIPPING WEIGHT
BTU / HR
126,000
126,000
176,000
158,000
Quote & Order Fax: 1-800-444-0602
n
1
" front
2
LBS / KG
367 / 167
467 / 213
648 / 295
726 / 330