Mitsubishi Electric MXZ-2F33VF-E1 Service Manual page 18

Outdoor unit, hfc utilized, r32
Hide thumbs Also See for MXZ-2F33VF-E1:
Table of Contents

Advertisement

Outdoor model
Outdoor unit power supply
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity Rated frequency (Min.-Max.) 2
Breaker capacity
Power input (Total) 1, 2
Running current (Total) 1, 2
Power factor (Total) 1, 2
Starting current (Total) 1, 2
Coeffi cient of performance (C.O.P) (Total) 1, 2
Model
Output
Current 1, 2
Refrigeration oil (Model)
Model
Current 1, 2
Dimensions W x H x D
Weight
Air fl ow (Rated)
Sound level (Rated)
Fan speed (Rated)
Pre-charged refrigerant quantity (R32)
Max refrigerant quantity (R32)
1 Measured under rated operating frequency.
2 When connected with indoor units below.
MSZ-LN18VG + MSZ-LN25VG + MSZ-LN25VG
NOTE: Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
COOLING INDOOR
Dry-bulb temperature 27.0 °C Wet-bulb temperature 19.0 °C
OUTDOOR Dry-bulb temperature 35.0 °C Wet-bulb temperature 24.0 °C
HEATING INDOOR
Dry-bulb temperature 20.0 °C
OUTDOOR Dry-bulb temperature 7.0 °C Wet-bulb temperature 6.0 °C
OBH790
m
m
m
Refer to 8 REFRIGERANT SYSTEM DIAGRAM.
m
Refer to 8 REFRIGERANT SYSTEM DIAGRAM.
Cooling
kW
6.8 (2.9 - 8.4)
A
W
1,840
A
8.4 - 8.0 - 7.7
%
A
3.70
W
A
L
A
mm
kg
3
m
/h
2,124
dB(A)
48
rpm
650
kg
kg
18
MXZ-3F68VF
Single phase
220 - 230 - 240 V, 50 Hz
2 to 3
Max. 60
Max. 25
Heating
8.6 (2.6 - 10.6)
25
1,910
8.8 - 8.4 - 8.0
99
10.1
SVB172FCKM1T
1,800
8.58
0.6 (FW68S)
SIC-82FX-F764-1
0.5
840 x 710 x 330
57
2,376
1.4
2.4
4.50
53
700

Hide quick links: