Mitsubishi Electric MXZ-2F33VF3 Installation Manual
Mitsubishi Electric MXZ-2F33VF3 Installation Manual

Mitsubishi Electric MXZ-2F33VF3 Installation Manual

Hide thumbs Also See for MXZ-2F33VF3:

Advertisement

Quick Links

Split-type Air-Conditioner
MXZ-2F33VF3
MXZ-2F42VF3
MXZ-2F53VF(H)3
English
INSTALLATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric MXZ-2F33VF3

  • Page 1 Split-type Air-Conditioner MXZ-2F33VF3 MXZ-2F42VF3 MXZ-2F53VF(H)3 English INSTALLATION MANUAL...
  • Page 2: For Installer

    FOR INSTALLER Required Tools for Installation CONTENTS ............1 Scale ..........Utility knife or scissors ........9 ..............1. BEFORE INSTALLATION MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT WARNING 1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY WARNING (Could lead to death, serious injury, etc.) Do not install the unit by yourself (user).
  • Page 3: Selecting The Installation Location

    This manual only describes the installation of outdoor unit. When installing the indoor unit, refer to the installation manual of indoor unit. CAUTION Install an earth leakage breaker depending on the installation place. Do not install the outdoor unit where small animals may live. Perform the drainage/piping work securely according to the installation manual.
  • Page 4 • 1-4-1. Minimum installation area for Outdoor units...
  • Page 5 15.5 Cassette...
  • Page 6 Only for MFZ 4.15 4.54...
  • Page 7: Installation Diagram

    1-5. INSTALLATION DIAGRAM WARNING ACCESSORIES Outdoor unit installation PARTS TO BE PROVIDED AT YOUR SITE Air inlet Air inlet Air outlet Extension drain hose (H) Putty 1-6. DRAIN PIPING FOR OUTDOOR UNIT...
  • Page 8 UNIT UNIT or dust. other refrigerant and do not allow air to remain in the lines. hazards. this could lead to a serious impediment to securing product safety. Thickness...
  • Page 9 Good Tilted Uneven Burred 5) Check Burr Clutch Clutch scratches. around Flare nut WARNING indoor units. When installing the unit, securely connect the refrigerant pipes before starting the compressor. Indoor unit: other CAUTION When there are the ports which are not used, make sure their nuts are tightened securely.
  • Page 10: Purging Procedures, Leak Test, And Test Run

    4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN 4-1. PURGING PROCEDURES AND LEAK TEST for GAS initial state.) Handle • Service control valve Control valve WARNING Close hazards or ignition risks before opening the stop valves. Body Union Indoor unit Union Outdoor Indoor...
  • Page 11: Pumping Down

    [How to lock the operation mode] HEAT 4-4. LOWERING THE OPERATION NOISE OF THE OUTDOOR UNIT [How to lower the operating noise] 4-5. TEST RUN About the restart protective mechanism 4-6. EXPLANATION TO THE USER 5. PUMPING DOWN WARNING When pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes.
  • Page 12 DECLARAÇÃO DE CONFORMIDADE CE EU-OVERENSSTEMMELSESERKLÆRING MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 20000, THAILAND hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...
  • Page 13 Importer: Capronilaan 46, 1119 NS, Schiphol Rijk, The Netherlands French Branch 25, Boulevard des Bouvets, 92741 Nanterre Cedex, France German Branch Belgian Branch Autobaan 2, 8210 Loppem, Belgium Irish Branch Italian Branch (MB), Italy Norwegian Branch Gneisveien 2D, 1914 Ytre Enebakk, Norway Spanish Branch Scandinavian Branch UK Branch...

This manual is also suitable for:

Mxz-2f42vf3Mxz-2f53vf(h)3

Table of Contents