4.14 POWER DISTRIBUTION BOARD

520-5343-01
ID
Type
Pin Description
CN1 .156 in 7-Pin Housing
1
+48 VDC IN
Plug: 045-5259-07
2
+48 VDC IN
Pin: 055-5331-00
3
+48 VDC IN
Key: 060-5013-00
4
Key (n/c)
5
Ground
6
Ground
7
Ground
CN2 .093 in 3-Pos Plug
1
Line In (100-240 VAC)
Plug: 045-5003-03
2
Neutral
Pin: 055-5013-09
3
Earth Ground
CN3 0.084 in 4-Pos Plug
1
+48 VDC to CPU Node
Plug: 045-5200-04
2
Door Interlock Switch Status
Pin: 055-5033-08
3
Line Voltage Status
4
Ground
CN4 0.084 in 6-Pos Plug
1
Door Interlock Switch +48V
Plug: 045-5200-06
2
Door Interlock Switch +48V
Pin: 055-5033-08
3
Switched 48V Out (to Node 1) GRY/YEL
4
Door Interlock Return Ground -
5
Door Interlock Return Ground -
6
Ground (to Node 1)
CN5 0.084 in 12-Pos Plug
1
Switched 48V Node Power
Plug: 045-5200-12
2
Switched 48V Node Power
Pin: 055-5033-08
3
Switched 48V Node Power
4
Switched 48V Node Power
5
Switched 48V Node Power
6
Switched 48V Node Power
7
Node Ground
8
Node Ground
9
Node Ground
10 Node Ground
11 Node Ground
12 Node Ground
CN6 .156 in 3-Pos
1
Ground
Plug: 045-5259-03
2
Ground
Pin:055-5331-00
3
+12VDC
(18awg)
CN7 .084 2-Pos
1
+48 VDC to CPU Node
Plug: 045-5200-02
2
Ground
Pin:055-5033-08
© 2016 Rag Doll Merchandising, Inc. Under License to Epic Rights.
ELECTRONIC PINOUTS AND SCHEMATICS

4.15 POWER PLUG WIRING

CAUTION
TO MAINTAIN SAFETY, GROUND WIRE FROM LINE FILTER
IS TO BE MOUNTED FIRST ON GROUNDING STUD AND
SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE
ATTACHED TO GROUNDING STUD.
REPLACE ALL FUSES WITH CORRECT CURRENT RATINGS!
NORTH AMERICA
Wire Color
GRY
GRY
GRY
-
BLK
POWER SUPPLY
BLK
POWER DIST.
BLK
BILL VALIDATOR
BLK
(USER INSTALLED OPTION)
WHT
INTERNATIONAL
GRN
*MFG NOTES:
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
GRY
2.
NEMA 5-15 OUTLET HAS 14AWG 600V WIRE, UL 1015, CSA TYPE TEW.
3.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
GRY/RED
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
GROUNDING STUD.
VIO
4.
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
BLK
-
-
POWER SUPPLY
POWER DIST.
LINE CORDS
BLK
GRY
GRY
*MFG NOTES:
Part Number
GRY
1.
ALL DISCREET WIRE IS 16AWG 600V, UL 1015, CSA TYPE TEW.
034-6012-00
2.
GROUND WIRE FROM LINE FILTER IS TO BE MOUNTED FIRST ON GROUNDING STUD
GRY
AND SECURED WITH NUT. ALL OTHER GROUNDS MAY THEN BE ATTACHED TO
034-6012-01
GROUNDING STUD.
3.
GRY
CABLE ARE TO BE MANUFACTURED IN A UL CERTIFIED FACILITY. VENDOR IS TO
034-6012-02
PROVIDE A SIGNED U.L. CERTIFICATE OF COMPLIANCE WITH FIRST ARTICLE.
GRY
034-6012-03
BLK
034-6012-04
BLK
034-6012-05
BLK
034-6012-06
BLK
034-6012-07
BLK
034-6012-08
BLK
034-6012-09
-
LINE FUSES
-
-
Line Voltage (Region)
120V (North America)
-
220/240v (Europe, Australia,
-
UK)
AEROSMITH LE / PREMIUM MANUAL 500-55I6-01
NORTH AMERICA
NEMA 5-15 PREWIRED OUTLET
L
LINE FILTER
G
N
GROUNDING
STUD
INTERNATIONAL
ON/OFF SW
L
LINE FILTER
G
N
GROUNDING
STUD
ON/OFF SW
Description
Line Cord, 3m, 5-15P USA
Line Cord, 3m, CEE77P EUROPE
Line Cord, 3m, BS1363P United Kingdom
Line Cord, 3m, AS-NZS4417P Australia
Line Cord, 3m, CEI23-16P Italy
Line Cord, 3m, SEV1011P Switzerland
Line Cord, 3m, JIS8303P Japan
Line Cord, 3m, SI32P Israel
Line Cord, 3m, BS546P S Africa, India
Line Cord, 3m, IS6538P S. India
Fuse
Type
Current
8 A
Slow Blow MDL
5 A
Slow Blow MDL
FUSE
FUSE
05/02/14
AC WIRI
1.00"
2.00"
1:1
SPIKE
05/02/14
1.00"
2.00"
1:1
Part Number
200-5000-05
200-5000-01
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aerosmith premium500-55i6-01500-55i7-01

Table of Contents