10
170S5 LCD
Go to cover page
Front Control Panel
Access Factory Mode
How to get into Factory Mode Menu
Step1:
Turn off monitor.
Step2:
[Push AUTO "
" & OK "
+[Press power "
" button untill comes out "Windows screen" ]
=> then release all buttons
Step3:
Press OK "
" button, bring up Factory mode indication as shown
in Fig2.
Factory Menu
Cursor can move on gray color area
Hot key function: by pressing " up " and " DOWN " key
Simultaneously at User Mode (or Factory Mode)
(PS: The Offset R G B function can be used on reduce or eliminate
snowy noise on the background when the resolution of video signal
is 1280*1024 vertical 60Hz. Slightly increase or decrease the value
until snowy noise completely disappear

Factory Mode

" buttons at the same time and hold it]
Mean: it is not
1280*1024
resolution now
Factory Mode indicator
Hudson 170S5 T024 2004-01-06
BL
: Black level value
SUB- BRI
: Brightness value range( Min Max )
SUB- CON : Contrast value range( Min Mid Max )
SRGB- B
: Brightness of sRGB
SRGB- C
: Contrast of sRGB
Gain- m
: Minimum value of User Gain
Gain- M
: Maximum value of User Gain
AUTO- SUB : To do Auto color function when push Menu key in white
pattern
OSDTIMER : OSD time out control( sec)
IDX
: Limit current of inverter
SCALER
: Read/Write scaler register
Panel
: HS ( Hannstar panel )
CPT(CPT panel
LG ( LG. Philips panel )
AU
QDI ( Quanta Display Inc.)
DEFAULT
SUB- CON:
Contrast adjustment (Sub - Contrast).Use this menu item
to adjust the contrast gain of pre-amp ranges from 0 to
255.
9300 K
R G B
6500 K
R G B
Color temperature gain adjustment. Use these menu
items to adjust the RGB gains of pre-amp for different color
temperatures, ranges from 0 to 255
OFFSET R G B:
Sub-Brightness adjustment. Use this menu item to adjust .
The brightness level (DC - level) of pre-amp range from 0
to 255. (R/G/B ANALOG DC-level)
GAIN R G B:
R/G/B GAIN adjustment. Use this menu item to adjust the
R/G/B (GAIN) of Amp. Range from 0 to 255.