Front control panel
Access Factory Mode
How to Get into Factory Mode Menu
Step 1 :
Turn off monitor.
Step 2 :
[Push AUTO "
" & OK "
it ] + [Press power "
" button untill comes out "Windows screen"
] => then release all buttons.
Step 3 :
Press OK "
" button, bring up Factory mode indication as
shown in Fig 2.
HUDSON 150S5 T031 2003-12-12
Factory menu
Cursor can move on gray color area
(PS: The Offset R G B function can be used on reduce or eliminate
snowy noise on the background when the resolution of video signal is
1024 X 768 vertical 60Hz. Slightly increase or decrease the value
until snowy noise completely disappear.)
All manuals and user guides at all-guides.com

Factory mode

Fig. 1
" buttons at the same time and hold
Fig. 2
<------Factory mode indicator
Hudson 150S5 V203 20030418
SUB - BRI :
SUB - CON :
100 130 160
9300K
R
Xxx G
6500K
R
Xxx G
SRGB
R
Xxx G
OFFSET2
R
Xxx G
GAIN
R
Xxx G
AUTO-SUB
OK! OSDTIMER
IDX :
OFFSET1
R
Xxx G
SCALER:ADD:
PANEL:
LG
1024x768 48.3KHz @60Hz
SUB-BRI
: Brightness value range(Min Max)
SUB-CON
:Contrast value range(Min Mid Max)
SRGB-B
: Brightness of sRGB
SRGB-C
: Contrast of sRGB
Gain-m
:Minimum value of User Gain
Gain-M
:Maximum value of User Gain
AUTO-SUB
:To do Auto color function when push Menu
Key in white pattern
OSDTIMER
:OSD time out control(sec)
IDX
:Limit current of inverter (CPT: 28)(LG: 7)
Panel Type
:PLS reference section 4
SCALER
:Read/Write scaler register
Panel
:CPT (CPT panel)
LG (LG.Philips panel)
-
SUB
SUB
CON:
CON:
Contrast adjustment (Sub-Contrast). Use this menu item to
adjust the contrast gain of pre-amp ranges from 0 to 255.
9 3 0 0 K R G B
6 5 0 0 K R G B
Color temperature gain adjustment. Use these menu items
to adjust the RGB gains of pre-amp for different color
temperatures, ranges from 0 to 255.
OFFSET R G B
Sub-Brightness adjustment. Use this menu item to adjust
the brightness level (DC-level) of pre-amp range from 0 to
255.(R/G/B ANALOG DC -level).
GAIN
R G B
R/G/B GAIN adjustment. Use this menu item to adjust
the R/G/B (GAIN) of Amp. range from 0 to 255.(R/G/B
ANALOG GAIN Values).
150S5
Go to cover page
xxx B
xxx
xxx B
xxx
xxx B
xxx
B
255 C 128
xxx B
xxx
xxx B
xxx
M 255 m 200
60
7
xxx B
xxx
WRITE