SERIAL SERVER CH1 AND CH2 MODBUS REGISTERS
SS1,2 Registers
Register
Bit
R/W
Number
41500-42523
[15:0]
R/W
42524-42779
[15:0]
R/W
42780-43035
[15:0]
R
43036-43291
[15:0]
R/W
43292-43547
[15:0]
R
SS1,2 Indirect Access Registers
Register
Bit
R/W
Number
43548
[15:0]
R/W
43549
[15:0]
R/W
43550-44061
[15:0]
R/W
44062
[15:0]
R/W
44063
[15:0]
R/W
Focal Technologies Corporation
A Moog Inc. Company
Description
Reserved
SS1 EEPROM Registers
SS1 GP Registers
SS2 EEPROM Registers
SS2 GP Registers
Description
uC ID
uC Data Start Address
uC Data
uC Number of Bytes
uC Operation
Model 922-DSLH – User Manual
Comments
For EEPROM registers
see section 0
For general purpose (GP) registers
see section 0
Comments
Set to 3 or 4 to select target uC 1 or 2 respectively
0x01-Reset uC, 0x02-Write Data to EEPROM, 0x03-
Write Data to uC GP Registers, 0x04-Command
Failed Flag. This register will is self-clearing to 0x00.
If command failed will return 0x04.
Document No. 922-0677-00, Rev 1.0
Page 10-5