Table 5-4: Carrier Board Diagnostic Leds - Focal 922-DSLH User Manual

Dsl hybrid gateway
Table of Contents

Advertisement

Reference
Name
Designator
D1
DSL FAULT
D2
DSL LINK
D3
CU1 SPD
D4
CU1 ACT
D5
CU1 DUP
D6
CU2 SPD
D7
CU2 ACT
D8
CU2 DUP
D9
SFP LINK
D10
SFP LOS
D11
PWR
D12
DC1
D13
SS1 ACT
D14
SS2 ACT
D15
A-B ACT
D16
B-A ACT
Notes:
1. LEDs in the table above are green color when on.
2. LEDs are valid for cards with uc DAIG FW version >= 0xA4.
Focal Technologies Corporation
A Moog Inc. Company

Table 5-4: Carrier Board Diagnostic LEDs

Factory use LED.
OFF = No DSL Link.
ON = DSL Link Up (initialization completed successfully).
Ethernet Speed CU1:
ON = Linked at 100Base-Tx.
OFF = Linked at 10Base-T.
Ethernet Link/Activity CU1:
OFF = No Link.
Solid ON = It indicates there is a link for 10Base-T or 100Base-TX, but no data is being
transmitted or received.
Blinking = It indicates data is being transmitted or received for either 10Base-T or 100Base-TX.
Ethernet Duplex Mode CU1:
ON = Full Duplex.
OFF = Half Duplex.
Ethernet Speed CU2:
ON = Linked at 100Base-Tx.
OFF = Linked at 10Base-T.
Ethernet Link/Activity CU2:
OFF = No Link.
Solid ON = It indicates there is a link for 10Base-T or 100Base-TX, but no data is being
transmitted or received.
Blinking = It indicates data is being transmitted or received for either 10Base-T or 100Base-TX.
Ethernet Duplex Mode CU2:
ON = Full Duplex.
OFF = Half Duplex.
ON = Optical link good.
OFF = No optical link.
ON = SFP RX power low.
OFF = SFP RX power good.
ON = Power Good (card is on).
OFF = Card is Off.
DSL and on-board Ethernet switch link:
OFF = No Link.
Solid ON = Internal Ethernet link between DSL daughter card and Ethernet switch.
Blinking = Ethernet TX/RX Activity.
Note: Normally this LED is ON or blinking when a DSL daughter card is installed.
OFF = No Link.
Solid ON = Internal Ethernet link between Serial Server CH1 and Ethernet switch.
Blinking = Ethernet TX/RX Activity.
Note: Normally this LED is ON or blinking.
OFF = No Link.
Solid ON = Internal Ethernet link between Serial Server CH2 and Ethernet switch.
Blinking = Ethernet TX/RX Activity.
Note: Normally this LED is ON or blinking.
OFF = No Link.
Solid ON = Internal Ethernet link between SWA and SWB.
Blinking = Ethernet TX/RX Activity.
Note: Normally this LED is ON or blinking.
OFF = No Link.
Solid ON = Internal Ethernet link between SWB and SWA
Blinking = Ethernet TX/RX Activity.
Note: Normally this LED is ON or blinking.