PACKAGED TERMINAL AIR CONDITIONER USER MANUAL FOR MODELS: 2PTC12A-3.0 2PTH15A-5.0 Before using your air conditioner please read this manual carefully and keep it for future reference, along with your receipt.
CONTENTS THE FOLLOWING WARNINGS ARE VERY IMPORTANT FOR SAFETY. UNIT FEATURES … ………………………………………… PLEASE READ THEM CAREFULLY BEFORE INSTALLATION! INSTALLATION INSTRUCTION … …………………………4 1. The air conditioner must be installed by WIRING … ……… ……………………………………… certified installer. OPERATING INSTRUCTIONS( … … … ACCESSORY OPTIONAL 2.
UNIT FEATURES High Pressure Protection: The unit will shut off automatically when the pressure in the system is over This unit has many features which are different than 638 psi and within 10 minutes, after the compressor those found on conventional PTAC units. The servicer turns off, the unit will restart when the pressure turns must be familiar with these features in order to properly back below 551 psi.
Fan Motors Permanently Lubricated All units Function Description Switches have two fan motors for quiet operation and maximum ON - When the unit is connect- operating efficiency. ed to the power supply, and the room temperature is lower Motors are permanently lubricated to reduce maintenance and completely enclosed to keep dirt than 10°C/50°F for 3 min., the unit will start heating automati-...
INSTALLATION INSTRUCTIONS To ensure that the unit operates safely and efficiently, it must be installed, operated and maintained according to these installation and operating instructions and all local codes and ordinances or, in their absence, with the latest edition of the National Electric Code. The proper installation of this unit is described in the following sections.
Page 6
OUTDOOR GRILLE (SOLD SEPERATELY) An outside grille must be installed to direct air flow for • Remove shipping tape from front panel as shown in Figure 12 on page 8 proper unit operation and also protect the outdoor coil. The grille must be installed before installing the chassis.
WIRING Operating Voltage Voltage Utilization Range Unit Voltage Cord connection to a wall socket is not permitted for 265V Rating Minimum Maximum units. All 265V units must be hard wired using the hard 230/208 wire kit or make use of the plug in receptacle in the standard subbase.
OPERATING INSTRUCTIONS Operation mode button s Receiver of IR remote controller signal Fan Speed button Press these buttons to Press this button to select select the unit operating mode: the fan speed on high, low or Heat, Cool, or Fan. The auto.
COOL/FAN/HEAT MODE OPERATION : unit control panel has control of unit. PROCEDURE Control panel: Press the ON/OFF button. VENTILATION CONTROL Press the Heat, Cool, or Fan button to select the operation mode. The ventilation control lever is located on the left side Press + or - button, to set your desired temperature.
3. Remove the seven (7) screws which secure the WARNING discharge air grille to the front cabinet. HIGH VOLTAGE DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES BE PRESENT, FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Page 11
2. Pull the filter straight up and remove. Routine scheduled Maintenance 3. Clean filter with a vacuum or with running water. To achieve continuing top performance and high efficiency, establish a “once a year" cleaning/inspection schedule Reverse this procedure to reinstall the filter for the unit.
4. Tilt the non-compressor side of the unit up no higher Air sounds than 45 degrees and allow water to drain out the other side The fan cycle switch sets the operational mode of the fan of the unit. In the ON position the fan will run continuously whenever 5.
TROUBLESHOOTING POSSIBLE CAUSES SOLUTIONS UNIT DOES NOT START ● Check that plug is plugged securely in wall receptacle. ● Unit may have become unplugged Note :Plug has a test/reset button on it. Make sure that the ● Fuse may have blown plug has not tripped.
Page 16
Distributed by: Perfect Aire, LLC 5401 Dansher Rd. Countryside, IL 60525 844-4PA-AIRE | 844-472-2473 www.perfectaire.us PA/Manual_2PTC_2PTH/04032018 Specification and performance data is subject to change without notice. Printed in China...
Need help?
Do you have a question about the 2PTC12A-3.0 and is the answer not in the manual?