Changing Fortimail-5001A Sw11 Switch Settings - Fortinet FortiMail-5001A Hardware Manual

Hide thumbs Also See for FortiMail-5001A:
Table of Contents

Advertisement

Changing FortiMail-5001A SW11 switch settings

Changing FortiMail-5001A SW11 switch settings
10
The SW11 switch on the FortiMail-5001A board is factory set by Fortinet to detect a shelf
manager
(Figure
4). This is the correct setting if you are installing the FortiMail-5001A
board in a chassis that contains an operating shelf manager (such as the FortiGate-5140
or FortiGate-5050 chassis).
Figure 4: FortiGate-5140 and 5050 setting for SW11 (factory default shelf manager mode)
Factory Default (Shelf Manager Required)
ON
1 Off
2 On
SW11
3 Off
4 Off
1
2
3 4
By default a FortiMail-5001A board will not start up if the board is installed in a chassis,
such as a FortiGate-5020, that does not contain a shelf manager or that contains a shelf
manager that is not operating. Before installing a FortiMail-5001A in a FortiGate-5020
chassis or a chassis that does not contain an operating shelf manager you must change
the SW11 switch setting as shown in
Figure 5: FortiGate-5020 setting for SW11 (standalone mode)
Standalone Mode for FortiGate-5020
(no Shelf Manager)
1 Off
ON
2 On
SW11
3 On
4 Off
1
2
3 4
In all cases you should confirm that you have the correct SW11 setting before installing
the board in a chassis.To change or verify the SW11 switch setting
Table 3: FortiMail-5001A SW11 settings for different chassis
Chassis
FortiGate-5140 or 5050 or any
ACTA chassis with an
operating shelf manager
(factory default shelf manager
mode).
FortiGate-5020 or any ACTA
chassis without an operating
shelf manager (standalone
mode).
To complete this procedure, you need:
A FortiMail-5001A board
A tool for changing the SW11 switch setting (optional)
Figure
5.
Correct SW11
Result of wrong jumper setting
Setting
1
Off
Shelf manager cannot find
FortiMail-5001A board. No shelf
2
On
manager information about the
FortiMail-5001A board available.
3
Off
4
Off
1
Off
FortiMail-5001A board will not start up.
2
On
3
On
4
Off
Hardware installation
FortiMail-5001A Hardware Guide
Version 3.0 MR5
http://docs.fortinet.com/
Feedback

Advertisement

Table of Contents
loading