Henny Penny CombiMaster CM Operator's Manual page 30

Table of Contents

Advertisement

Cleaning
9
When the cleaning is finished, rinse the cabinet
down using the retractable hand shower. Be sure
to rinse behind the air baffle.
10
Wipe cabinet and door gasket with a damp
cloth. If needed open the inner glass door pane
and wipe down as well.
11
Close cabinet doors.
When the cabinet doors are closed, Hot Air mode
automatically switches on for 10 minutes to dry the
cabinet.
12
Exit the cleaning program by selecting a cooking
mode.
0:10
End
Note
• Leave the cabinet door slightly open if the unit
will be idle for a prolonged period (e.g.
overnight).
• To prevent corrosion of high-quality chrome
nickel steel, the unit must be cleaned regularly,
even if it is operated only at "Moist Heat ".
• If there is heavy soiling let the residues soften
for 10 minutes in "Moist Heat" mode before
cleaning.
• Do not treat unit with acids or expose to acid
fumes. This will damage the protective layer of
stainless steel and may cause discoloring in the
finish.
• Do not use high pressure cleaners.
• Rinse the spray pistol nozzle and nozzle
extension with clear water after every use.
• Rinse the cleaning bottle with warm water after
use.
• A couple of drops of salad oil will clear any
stiffness in the pump plunger.
- 29 -