Maximum Temperature Setting

1.
Pull off the temperature control knob.
2.
Remove the hub screw using the 3 mm hexagonal wrench (supplied) and remove
the temperature control hub.
3.
Rotate the flow divertor lever to bath mode.
4.
Rotate the cartridge temperature spindle using the temperature control hub until
the desired bath outlet temperature is obtained from the bath spout.
(clockwise = decrease temperature).
5.
Once the desired maximum blend temperature has been achieved (46°C is
recommended for bath fill), refit the temperature control hub without disturbing
the spindle, positioning the hub such that the lug on the temperature hub is
against the left hand side of the temperature stop sleeve (refer to illustration).
Check that the blend temperature has not altered, refit and tighten the hub locking
screw.
6.
Replace the temperature control knob.
Temperature
-
Temperature Spindle
Hub Screw
+
Maximum Temperature Setting
Temperature Control Knob
Temperature Control Hub
17
Flow Divertor Lever
Temperature
Control Hub Lug
Temperature Stop Sleeve

Hide quick links: