4.
To remove the monitor or secondary
door interlock switch:
a) Disconnect the wire connector from the
terminals.
Monitor Switch
Locking Arm
Locking Arm
Secondary Switch
Wire Connectors
2-6
CAUTION: When you press in on the
locking arm to remove the switch in the
next step, be careful not to press in too far,
or you will break the arm off. If this hap-
pens, you will have to replace the entire
switch bracket.
b) Press in on the locking arm, (refer to the
previous photo), rotate the switch so it
is free of the arm, and pull the switch off
the pivot pin.
Rotate
Pivot Pin