The total system (indoor unit and outdoor unit) is designed
for combination with a Daikin domestic hot water tank. In
case another tank is being used in combination with the
Daikin indoor unit, Daikin cannot guarantee neither good
operation nor reliability of the system. For those reasons
Daikin cannot give warranty of the system in such case.

Main components

P
Q
B
C
D
Q
G
J
G
J
A
Hot water out connection (G 3/4" Female)
B
T-piece (field supply)
C
Pressure relief valve connection
D
Pressure relief valve (field supply)
E
Recirculation connection (G 1/2" Male)
F
Thermistor socket
G
Flow inlet connection from the main EKHBRD indoor unit at the
bottom of the tank (quick coupling)
H
Heat exchanger coil
J
Return outlet connection to the main EKHBRD indoor unit at the
bottom of the tank (quick coupling)
K
Cold water in connection (G 3/4" Female)
L
Thermistor
Installation manual
2
M
Anode
N
Service opening (Ø125 mm) (only for EKHTSP models)
P
Casing
Q
Knockout holes for water piping
Safety devices
The domestic hot water tank relief valve connections
may not be used for other purpose.
This domestic hot water tank can only be used with an
EKHBRD indoor unit.
Thermal protector — The EKHBRD indoor unit is equipped with
a thermal protector. The thermal protector is activated when the
temperature becomes too high. When activated, the protector
has to be reset on the indoor unit by pressing the red button (for
access, remove the decoration panels like indicated in the
manual of the indoor unit).
Switch off the power supply before opening the
decoration panels of the indoor unit.
Pressure relief valve — A pressure relief valve (field supply) in
accordance with relevant local and national regulations, and with
an opening pressure of maximum 10 bar must be connected to
M
the pressure relief valve connection.
F
If a discharge pipe is connected to the pressure relief device it
must be installed in a continuously downward direction and in a
frost-free environment. It must be left open to the atmosphere.
H
L

Outlook diagram

N
Outlook diagram, see
1
Hot water out connection (G 3/4" Female)
2
Cold water in connection (G 3/4" Female)
3
Hot water out connection at the bottom of the tank (quick coupling)
4
Cold water in connection at the bottom of the tank (quick coupling)
E
5
Recirculation connection (G 1/2" Male)
A
K
6
Flow inlet connection from the main EKHBRD indoor unit
(quick coupling)
7
Return outlet connection to the main EKHBRD indoor unit
(quick coupling)
8
3-way valve
9
Flow inlet connection from the main EKHBRD indoor unit at the
A
bottom of the tank (quick coupling)
10
Return outlet connection to the main EKHBRD indoor unit at the
bottom of the tank (quick coupling)
E
11
Service opening (Ø125 mm) (only for EKHTSP models)
12
Knockout holes for water piping
13
Levelling feet (EKHBRD unit only)
K
Domestic hot water tank model
EKHTS200A, EKHTSP200AA
EKHTS260A, EKHTSP260AA
Domestic hot water tank for air to water heat pump system
figure
2.
H
2010 mm
2285 mm
EKHTS200+260A + EKHTSP200+260AA
4PW53247-1B