Domestic hot water heat pump monobloc type (40 pages)
Summary of Contents for Daikin EKHTS200A
Page 1
INSTALLATION MANUAL Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA EKHTSU200AA EKHTSU260AA EKUHWHTA...
P = Special version with service opening (125 mm) OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY Standard version when no letter is mentioned TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE Hot water Tank Stainless steel SPECIFICALLY DESIGNED FOR USE WITH THE...
Service opening (Ø125 mm) (only for EKHTSP models) The total system (indoor unit and outdoor unit) is designed Casing for combination with a Daikin domestic hot water tank. In Knockout holes for water piping case another tank is being used in combination with the...
EKHTS Provide a connection for the pressure relief valve and drain on NSTALLATION OF THE DOMESTIC HOT the cold water inlet. WATER TANK To avoid back siphonage it is advised to install a non-return valve on the cold water inlet of the domestic hot water tank in accordance with local and national regulations.
Page 6
3 Unpack the 3-way valve body and 3-way valve motor. 5 Install the 3-way valve body in the piping. Verify that following accessories are provided with the motor. Refer to the figure below before making the connection. Sleeve Valve motor cover Screw Turn knob 4 Put the sleeve on the valve and turn the valve so that the...
Page 7
9 Perform the wiring in the indoor unit switch box in accordance Fix the side bottom decoration panels of the domestic hot water with the following figure: (make sure power supply is tank to the indoor unit. switched off) 3-way valve Make sure to follow the appropriate wiring routing inside of the unit (this wiring routing can be found in the installation manual of the indoor unit).
3 When routing out cables, make sure that these do not 12 Reattach front obstruct mounting of the indoor unit cover. decoration panel of the domestic water Note: only relevant field wiring is shown. tank. 3-way valve 13 Reattach front >50 mm N Y L decoration panel of the...
Only for domestic hot water tanks with a service opening ROUBLESHOOTING (EKHTSP): For cleaning of the hot water tank interior and the heat This section provides useful information for diagnosing and exchanger, remove front decoration panels and insulation piece, correcting certain troubles which may occur in the unit. drain the domestic hot water tank and remove the service cover with a socket spanner of 32 mm, like indicated in the figure below.
ECHNICAL SPECIFICATIONS Domestic hot water tank specifications EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA Storage capacity Internal heat exchanger volume Material Stainless steel Stainless steel Stainless steel Stainless steel Overall dimensions (h x l x w) 1335 x 600 x 695 1610 x 600 x 695...