SPECIFICATIONS
Air
Voltage
direction
(V)
Supply
120
Performance based on the MERV8 filter (FV-FL0815NL1), and data with " * " is a reference
datas when using the MERV13 filter (FV-FL1315NL1).
Air volume performance based on HVI Procedures 916 and 920.
PRODUCT SERVICE
Warning Concerning Removal of Covers.
The unit should be serviced by qualified technicians only.
Your product is designed and manufactured to ensure a minimum of maintenance.
Should your unit require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA)
or 1-800-669-5165 (Canada).
Two Riverfront Plaza, Newark, NJ 07102
www.panasonic.com
Panasonic Corporation 2018
12
Frequency
Duct
(Hz)
(inch)
60
6
Static
Air volume
pressure
(CFM)
50/50*
60/60*
70/70*
80/80*
0.2"WG
90/90*
100/100*
110/110*
130/130*
150/150*
5770 Ambler Drive, Mississauga, Ontario L4W 2T3
www.panasonic.com
Power
Speed
consumption
(rpm)
(W)
8/8.2*
969/989*
9/9.3*
992/1012*
10/10*
1022/1033*
12/12.4*
1030/1067*
13/13.5*
1056/1086*
15/15.3*
1101/1121*
16/16.7*
1122/1152*
21.5/22.6*
1202/1235*
27.1/27.3*
1296/1314*
Issue date:01/2018
P0118-0 15NLF4051
Weight
kg
Ib.(
)
13.4
(6.1)
Printed in China