Maintenance - Panasonic FV-15NLFS1 Installation And Operating Instructions Manual

In-line fan
Hide thumbs Also See for FV-15NLFS1:
Table of Contents

Advertisement

OPERATION
Temperature dial switch
6
Adjusting the temperature protection value of the product by this dial switch, you can
choose 15 °F ~ 40 °F (stepless) or turned to OFF position.
Default setting : 15 °F
If the product inside temperature detected by sensor is lower than setting value, the fan
will stop for 60 minutes, then according to the detected value to determine whether to
operate.
If the product inside temperature detected by sensor is higher than 95 °F (35 °C), the fan
will stop for 60 minutes, then according to the detected value to determine whether to
operate.
If the switch is turned to OFF position , the temperature sensor detection function will
be disabled.
Note
The humidity and temperature value detected by sensor may be different from outside.

MAINTENANCE

CAUTION
To avoid injury or electric shock, turn off the main switch in control box to stop the fan
before checking, cleaning or replacing filter.
To ensure product running normally, routine maintenance must be performed every
3 months.
Please wear gloves to avoid pinching fingers during maintenance.
When cleaning or replacing filters, dust, insects, etc. attached on the filters may fall.
Please pay attention to the protection of eyes and so on.
1.
Open the control box cover by twist hand
1
screw. (Fig.13)
2
Turn off main switch. (Fig.13)
Twist hand screw open maintenance board.
3
(Fig.13)
2.Pull out the pre-filter, clean it with water once in
3 months when filter indicator lights on with
buzzer sound "Pi-Pi-Pi- ... ". (Fig.14)
10
3
1
Pre-filter
2
Fig.13
Fig.14