Download Print this page

Telcoma STONE 300 GR Installation Manual page 16

Operators for swing gates 220v

Advertisement

Function
n.
Off - On
OFF
OFF
ON
OFF
3
JOLLY
INPUT MODE
4
OFF
ON
ON
ON
OFF
5
PREFLASH
ON
OFF
RE-CLOSURE
6
TIMER
ON
OFF
7
US1 OUTPUT
ON
OFF
GATE
8
RELEASE
JOLT
ON
OFF
9
SLOWDOWN
ON
OFF
POWER
10
CLOSING
JOLT
ON
OFF
11
1 - 2 MOTORS
ON
OFF
RECLOSING
AFTER THE
12
PHOTOELECTRIC
CELLS
ON
Mode
J1=TIMER input; closes the gate when the contact is opened and
J1 = TIMER
opens it when the contact is closed.
J2=third photocell input (FT3); intervenes only during opening and
J2 = FT3
forces closing. Use N.C. contacts.
J1 = FCA M1
Stops only motor M1 using electric travel limits.
Use N.C. contacts
J2 = FCC M1
J1 = FCA M1
Motors are stopped during OPENING using electric travel limits.
Use N.C. contacts
J2 = FCA M2
J1 = FCA M1
For installations with 4 travel limits. Connect the travel limits of motor M1
J2 = FCC M1
to the inputs FCC and FCA. Connect the travel limits of motor M2 to the
PA = FCA M2
inputs J1 and J2.
PC = FCC M2
Use N.C. contacts
EXCLUDED
The flashing light operates together with the motor.
INSERTED
The flashing light operates 5 seconds before any operation.
After one complete opening, the control unit only closes again with a
EXCLUDED
manual control.
After one complete opening, the control unit closes automatically after the
INSERTED
programmed pause time.
This contact gives information regarding the status of the gate.
Dray contact
The relay activates as the gate begins to open and deactivates only
after complete closing has been achieved.
Second radio channel output. If you don't use this function the second
Channel 2 (OC2)
radio channel will activate pedestrian opening.
EXCLUDED
Function excluded.
The gate release jolt is needed to release the electric lock.
INSERTED
The gate with M1 installed will carry out a brief closing movement before
starting the opening cycle.
EXCLUDED
There is no slowdown in the last part of travel.
INSERTED
With the slowdown function connected, the motor halves its speedtowards
EXCLUDED
Power closing is not carried out.
The ECU will end the closing manoeuvre with a brief increase to full power
INSERTED
on motor M1.
Only the M1 output is enabled. The pedestrian command partially opens
1 MOTOR
and closes motor M1
Enables both motor outputs (M1 and M2). The pedestrian command
2 MOTORS
completely opens and closes the gate with motor M1.
EXCLUDED
Function excluded.
The activation of photoelectric cell reduces the pause time for whatever
INSERTED
is value previously was to 2
Descrption
GB
16

Advertisement

loading

This manual is also suitable for:

Stone 400 grStone 600 grT600