Term. n.
20 (CON.)
21 (CON.)
M1
22 (AP)
23 (CH)
24 (Com)
25 (-)
ENC
26 (+)
1
27 (D)
40 (CON.)
41 (CON.)
M2
42 (AP)
43 (CH)
44 (Com)
45 (-)
ENC
46 (+)
2
47 (D)
28 (no)
US1
29 (nc)
30 (c)
24V
31
32 (0)
24V FT
33
34 (0)
24V
35
34 (0)
12V
36
37 (0)
38 Calza
39 Cent.
Function / Device
Output motor M1
Encoder sensor input motor M1
Output motor M2
Encoder sensor input motor M2
Contact for selectable functions
Output for auxiliary device power
supply
Output for Transmitter / Photocell
power supply
Indicator light output
Electric lock output
Receiver aerial input
V/I max
/
Motor M1 moves first in the opening direction and is
/
delayed during closing.
230/4A
An eventual electric lock should be fitted to this gate
leaf.
/
For the motor-ECU connection use a separate cable
5-12V
/
(e.g. 3x0,35) with a max. length of 10m
/
/
M2 is the second motor to move and the first one to
230/4A
close.
/
For the motor-ECU connection use a separate cable
5-12V
/
(e.g. 3x0,35) with a max. length of 10m
/
/4A
See settings for dip 7 (part. 19 fig. A)
e.g. photocells, external receivers or other 24Vac
24ac/0,5A
/
devices
Output only active during the manoeuvre and the
/
reclosing pause period, connect the photoelectric
24ac/0,5A
cell projectors so that the minimum amount of
power is used. If the jumper (part. 9 di fig. A) is set
to ON this output will be continuously active.
Status indication:
automation CLOSED – led off
/
during OPENING – flashes slowly
24ac/0,2A
during CLOSING – flashes quickly
STOP (block) – remains lit
during the RECLOSING PAUSE – double flashing
with pause
Activates, for a couple of seconds at the beginning
12dc/1,5A
/
of each opening cycle
/
Connection is only necessary if OC2 is inserted