2.7.

BEFORE TAKE-OFF

Before proceeding with a ground run-up, be sure that the propeller system is purged, by
feathering the propeller once or twice with the Power Lever in the idle position. Items a –
d below should be used to check the Propeller over speed governor:
Hold the Elevator Control firmly FULL UP during all
high power ground operation to keep the airplane from
nosing over.
a.
Place the propeller lever in full increase RPM (forward) position.
b.
Increase RPM with the power lever at least to 1800 RPM.
c.
in RPM.
d.
Reduce power back to idle.
Flight Controls – Check free and correct.
e.
Elevator Tab – SET for take-off
f.
Flaps – Flaps 15 to achieve para. 4.5 take-off performance.
g.
Prop Control – FORWARD high RPM.
h.
Strobe Lights – ON
i.
Determine takeoff distance per Para. 4.5 "Take-off Distance to reach 50 ft
j.
above ground level".

2.8. NORMAL FLIGHT PROCEDURES

Take-Off
a.
Brakes
b.
Power Lever
c.
After breaking ground, allow airspeed to build up to best-rate-of-climb
speed of 106 MCAS and retract flaps.
AFM H8001 SINGLE & DUAL COCKPIT Revision B
FAA APPROVED: 3/19/2015
CAUTION
Momentarily exercise the prop test switch and check for a small decrease
NOTE:
Best rate of climb is achieved with flaps up.
S2R-H80 Single & Dual Cockpit
AIRPLANE FLIGHT MANUAL
RELEASE
ADVANCE. Do not exceed engine
operational limitations.
Page 25