Connecting The 962 Control; Connecting The 962M And The 962S Control - Autotrol Magnum Cv 942 Installation And Service Manual

Magnum cv series; magnum it series
Table of Contents

Advertisement

5.4.1 Connecting the 962 Control

When the 962 control is used for single tank
applications, two standard connections are required for
operation: the power transformer and the flow sensor.
Figure 5.14 outlines these standard features as well as
how to connect the battery backup parallel connector
and the optional remote regeneration feature.
Wall Transformer
5.4.2 Connecting the 962M and the
962S Control
The 962M and 962S controls are used for twin
alternating tank applications. Five standard
connections are required for operation: the power
transformer, the flow sensor, feedback switches and
the connection between the 962M and 962S controls.
Figure 5.15 outlines these standard features as well as
the battery backup and the optional remote
regeneration feature.
Wall Transformer
Battery Backup
AC Power Jack
Battery Backup
Feedback Switch
962M
Flow Sensor
Figure 5.14
Important: The normally-closed position of the
feedback switch is protected with a rubber boot. DO
NOT REMOVE. The normally-closed position is not
available to provide an auxiliary electrical signal.
Flow Sensor
962 M + S
Connection
Figure 5.15
32
Parallel Connector
Optional Remote
Regeneration
Feature
Feedback Switch
962S
Optional Remote
Regeneration Feature