TechNIcAl DATA

voltage
max. current consumption
power cord
Acceptance capacity
max. operating pressure
volume flow at 12 mpa (120 bar) with water
max tip size
max. temperature of the coating material
max viscosity
Weight
High cart
Low cart
Special high-pressure hose
DN 6 mm, 15 m, connection thread M 16
x 1.5
Dimensions (l x W x h)
High cart
Low cart
Altitude
This equipment will operate correctly up
to 2000 m above mean sea level
vibration
Spray gun does not exceed 2.5m/s
max sound pressure level
* Place of measurement: 1 m distance from unit and
1.60m above floor, 12 MPa (120 bar) operating pressure,
reverberant floor
12
220~240 VAC, 50/60 Hz
7.5 A
See page 90
1725 Watt
221 bar (22.1 MPa)
3.0 l/min
0.029 inch – 0.73 mm
43°C
25.000 MPa·s
43.5 kg
43.5 kg
590 x 529 x 726 mm
1148 x 541 x 485 mm
80 dB*