Commissioning, inspection, maintenance
Checking the burner gasket and burner gauze...
B
Fig. 28
1. Remove electrode
B
2. Undo 2 Torx screws and remove thermal insulation
ring
.
C
3. Undo 2 Torx screws and remove burner gauze
assembly
with gasket
D
4. Insert and secure new burner gauze assembly
with new gasket
E
.
!
Please note
Tighten screws enough
to ensure the components do not suffer
damage and will function correctly.

Checking and adjusting the electrode

40
E
D
2x
.
.
E
D
(cont.)
A
C
5. Mount thermal insulation ring
!
Please note
Tighten screws enough
to ensure the components do not suffer
damage and will function correctly.
6. Fit electrode
.
B
!
Please note
Tighten screws enough
to ensure the components do not suffer
damage and will function correctly.
1. Check the electrode for wear and contamination.
2. Clean the electrode with a small brush (not a wire
brush) or emery paper.