Commissioning, inspection, maintenance
Further details regarding the individual steps
5. Refit thermal insulation ring C.
!
Please note
Tighten screws just enough
to ensure the components do
not suffer damage and will
function correctly.

Checking and adjusting the electrode

1. Check the electrode for wear and
contamination.
38
4
+0,5
(cont.)
6. Refit electrode B.
!
Please note
Tighten screws just enough
to ensure the components do
not suffer damage and will
function correctly.
2. Clean the electrode with a small
brush (not with a wire brush) or emery
paper.
3. Check the electrode gaps. If the gaps
are not as specified or the electrode
is damaged, replace electrode and
gasket and realign the electrode.
Tighten the fixing screws for the elec-
trode.
!
Please note
Tighten screws just enough
to ensure the components do
not suffer damage and will
function correctly.