4/00021-2/FEA 209 544/6 C
If the voltages at V608 are correct but the display is totally empty when phone is on, measure the voltages at the
display pads, H622 (fig. 3.4):
Pad #
Name
1
2
I
C-CLOCK
2
2
I
C-DATA
3
VDIG
4
VDIG
5
GND
6
VLCD
Table 3.1
If there isn't VLCD voltage at pad 6, measure the resistances from the pad to V608 pin 1 (~0 ohms) and from
pad 5 to GND (~0 ohms). If any of the resistances are too high there's a foil damage and the phone is to be dis-