Ericsson GF 768 Troubleshooting Manual page 14

Hide thumbs Also See for GF 768:
Table of Contents

Advertisement

Troubleshooting guide
All the values are 0.2V .
If any of the voltages are incorrect, measure the resistance of C633 (class A, >100 kohms, fig. 3.2) and C824
(class A, >25 kohms, fig. 3.2).
If any of the resistances are too low, replace the corresponding capacitor.
If the voltages and VRPAD are correct, replace the diode. If VRPAD is incorrect, go to chapter 6.
If the voltages at the diode (except VRPAD) are incorrect after replacing it, check the soldering at D600 pad
96.
Replace C632 (class A, fig. 3.2) and measure the voltages at V608 again. If the voltages still are incorrect,
replace D600 (class B, fig. 3.1).
14
4/00021-2/FEA 209 544/6 C
Fig. 3.2