Error Codes - PowerTec Digimax Installation And Operation Instruction Manual

Advanced microprocessor controlled digital speed/ratio controller
Table of Contents

Advertisement

CODE
00
01
02
03
04
05
06
07
08
09
10

ERROR CODES

ERROR CODES
ERROR CODES
ERROR CODES
ERROR CODES
During parameter entry, mistakes may be made. The DIGIMAX
values, and if the value is proper for the current parameter or mode of operation, the value
will be accepted and the parameter table changed. VALUES MAY NOT BE IMPLEMENTED
IMMEDIATELY IF TO DO SO WOULD UPSET THE CURRENT OPERATING SITUATION.
The DIGIMAX
current operation, such as changing the PPR rate (parameter #5) while the motor is running.
A stop cycle must be concluded before some parameters will become effective.
NOTE:
WHILE THE DIGIMAX
ONLY FUNCTION WHICH WILL OPERATE IS EMERGENCY STOP! ERROR MES-
SAGES SHOULD BE CLEARED IMMEDIATELY IF THE DIGIMAX
TION. ERROR MESSAGES WILL AUTOMATICALLY TIME OUT IN SIX SECONDS.
A table of error codes is presented above and explanations follow. Some of these
codes apply to specific parameters, and others are general. Section 3 gives some of the error
codes with illegal values in parameter entries.
ERROR CODE 01 -- SPEED GREATER THAN PARAMETER P-2
This error comes up in the MASTER mode when a new speed command is entered.
The speed entered is greater than the P-2 parameter. Press ENTER to clear the error code
and then reenter the speed command. If this speed is necessary, parameter #2 may have
to be changed. Make sure it is within the speed range of the motor.
DIGIMAX
Manual
® ® ® ® ®
MEANING
no error (not displayed)
Speed greater than parameter #2
Acceleration ramp time too small
Deceleration ramp time too small
Value greater than 255
Value greater than 65535
Value greater than 99999
Illegal decimal location
Illegal unit I.D.
Illegal mode value
Illegal baud rate
Table 2: Error codes for the DIGIMAX
will not put into effect immediately parameters which will radically alter the
®
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
IS DEALING WITH AN ERROR CONDITION, THE
® ® ® ® ®
SPEED GREATER THAN PARAMETER P-2
SPEED GREATER THAN PARAMETER P-2
SPEED GREATER THAN PARAMETER P-2
SPEED GREATER THAN PARAMETER P-2
CODE
MEANING
11
illegal up/down increment value
12
0 integer value not allowed
13
Parameter change not allowed
14
Jump up/dn value too large
15
Illegal attempt to change parameter
16
illegal protocol number
17
maximum ratio exceeded
18
maximum ramp value exceeded
19
illegal parameter number
20
maximum parameter value
21
less than minimum ratio
99
unknown error