3.0 Set Up Parameters - PowerTec Digimax Installation And Operation Instruction Manual

Advanced microprocessor controlled digital speed/ratio controller
Table of Contents

Advertisement

The DIGIMAX
applications. Most of these parameters alter the operating characteristics. There are default
parameters for general purpose usage, but the actual programming of these parameters
for any application is the responsibility of the user.
The unit is shipped from the factory with the default parameters unless it is shipped as
part of a system. If it is part of a system, it will be shipped with parameters which will be set
up according to the information which POWERTEC has available about how it will be used.
If a special setup has been requested, or is required, that is how it is shipped. Table I on page
14 and Table 1A on page 20 contain a list of the default parameters, which may be entered
from the table. After a DIGIMAX
to enter all parameter values into Tables I (page 14) and 1A (page 20) to maintain a record.
PARAMETER ACCESS
PARAMETER ACCESS
PARAMETER ACCESS
PARAMETER ACCESS
PARAMETER ACCESS
Access to the parameter list requires the knowledge of one of the two security codes:
a master maintenance code (printed at the end of this manual on a tear out page), and an
operator password (parameter #21). The maintenance code is built into software and cannot
be changed, except by the factory. The operator password may be changed at will by anyone
with access to the parameter tables.
Before following this procedure, read section 2.0 (ORIENTATION) of this manual.
Access to the parameters is gained by the following procedure:
It is not necessary to enter any leading zeroes. Enter 12, if that is the code. It is not
necessary to enter 00012, although that will work. The number "0" is a legitimate code. You
must press at least 1 digit to enter a code.
If the number has been incorrectly entered, the display will return to the display mode
it was in before the PGM/CLR button was pressed. If the number is correctly entered, the
display will show a "P-nn" ('nn' is a number from 1 to 41). That number will be the parameter
currently available for review. If this is the first access since power was applied, parameter
#1 will show (a "P-01" will be displayed). If there was a previous access since the last time
power was applied, the parameter visible when setup mode was exited will be showing.
If the DIGIMAX
(parameter #16 is set to "0") the display will flash "Err 15" (see page 31). Press the PGM/
CLR button again, and, if the display goes blank, press the PGM/CLR button to restore the
display. Wait until the RUN command is off before attempting to change parameters. The
parameters may be accessed as soon as the RUN input is off, even during deceleration.
If frequent access to the parameters is necessary, change parameter #16 to "1" to allow
access to the parameters while running, and change parameter #21 to "0" so that access to
the parameters may be gained very quickly by pressing the PGM/CLR button, "0", and the
ENT button..
Moving up in the parameter tables (#1 to #2 to #3, etc.) is accomplished with the UP
button. When parameter #41 is reached, pressing the UP button will roll over to parameter
#1. Moving down in the parameters (#10 to #9 to #8, etc.) is accomplished with the DN
button. Pushing DN when parameter #1 is showing will roll over to parameter # 41.
DIGIMAX
Manual
® ® ® ® ®
3.0 SET UP P

3.0 SET UP PARAMETERS

3.0 SET UP P
3.0 SET UP P
3.0 SET UP P
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
has 41 setup parameters which may be programmed for specific
®
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
1. Change from REMOTE to LOCAL, if necessary (REMOTE LED should be off).
2. Change to COMMAND mode, if necessary (display will be dimmed).
3. Press the PGM/CLR button (the display will blank out).
4. Enter the security code (a dash will appear for each number entered).
5. Press the ENTER (ENT) button.
DIGIMAX
DIGIMAX
DIGIMAX
DIGIMAX
is running, and parameter access is denied during run mode
®
6. Enter the desired parameters.
ARAMETERS
ARAMETERS
ARAMETERS
ARAMETERS
has been set up in a specific application, it is a good idea
®
Page
13