Error number
Reason
Err 1
A parameter value is invalid
Err 2
Command not recognised
Err 3
Numeric value is wrong format
Err 4
Wrong number of parameters
Err 5
This is a warning, not an error. One of the parameters is out of range. The
value of the parameter has been adjusted. For example, sending an RT
command with a delay of 0 will get a reply of "Err 5". The command will be
accepted and the delay set to the minimum allowed.
Err 8, 12
EEPROM corrupt. The configuration has been cleared.
Err 9, 20
Couldn't save settings to EEPROM.
Err 27
Can't read Ethernet settings from EEPROM, so these may be incorrect.
Err 33
The VTR1 is too hot. The VTR1 has a thermal cut-out that operates at about
O
65
c to 70
Any other errors are internal errors.
Event messages are sent when an error occurs. The format of these is:
Evt<channel>,<event code>;
These event messages are only sent after the GT1 command has been sent.
Event number
Reason
1 to 127
An error has occurred. The error code is given by the event number.
130
The temperature of the light is too high and operation has been stopped.
148
The allowed duty cycle is now normal (after event 149).
149
The allowed duty cycle has been reduced due to high internal temperature.
C. Error Codes
O
c, depending on conditions.
D. Event Codes
23