GARDASOFT VTR1 User Manual page 18

Strobe light
Table of Contents

Advertisement

18
Set the Option Flags
RE1,p
Where:
p = 0
P flag set (positive triggers)
p = 4
P flag cleared (negative triggers)
Set Internal Trigger
Enables or disables the internal trigger. When enabled, all outputs are triggered simultaneously
using an internal trigger signal. This setting can be saved to non-volatile memory using the AW
command.
TT0
Disable internal trigger
TT1
Enable internal trigger (uses previously set period)
TT1,p
Enable internal trigger and set the period
Where:
p= period of the triggers in milliseconds
For example:
TT1,200
TT1,1S
Save the settings to memory
AW
The results of the RW, RT, RE, TT commands are all saved. Once the settings are saved to
memory they are then retained when the unit is switched off. If this is not done, changes to
the settings are volatile, and if the unit is switched off they revert to those in force when the
last AW command was issued.
Clear Configuration
CL
Clears the configuration. The results of the RW, RT, RE, TT commands are all cleared.
Report the configuration
ST
Reports all the channel settings. Typical output is:
CH 1, MD 1, S 100.0 DL 10us, PU 1.000ms, RT 1.020ms, IP1,FL0, CS0.000A, RA24V
Where the numeric values are:
MD
Mode: 1 = pulse, 2 = switched
S
Brightness percentage setting
DL
Pulse delay
PU
Pulse width
RT
Retrigger delay
IP, FL, CS, RA Unused
Set the internal trigger to 200ms (5Hz)
Set the internal trigger to 1 second (1Hz)