DHCP mode or the IP address can be set and read the VTR1 Configuration Program available for
download at www.gardasoft.com.
8.2.2
Automatic Sensing
All the features below are implemented in a Configuration Program with C++ source code
available from www.gardasoft.com.
The VTR1 will send out a message on three events:
On power up
When an IP address is received or renewed by DHCP
When an enquiry message is received
On the first two events, the message is broadcast. On the third it is a reply to a single IP address.
An enquiry message is a UDP packet from source port 30310, destination port 30311 with the
message body "Gardasoft Search" (8-bit ASCII, 13 characters).
The message output by the VTR1 is a UDP packet from source port 30311, destination port
30310. It is formatted as:
Gardasoft,VTR1,000000,111111111111,22222222
(8-bit ASCII, 44 characters), where
000000
111111111111
22222222
For example for VTR1 serial number 12345, IP address 192.168.1.103, MAC address
00.0B.75.01.80.99 the packet contains:
Gardasoft,VTR1,012345,000B75018099,C0A80167
the serial number of the unit
the MAC address in 6 HEX bytes
the IP address in 4 HEX bytes