12
Mode
Trigger Input
Pulsed
Trigger rising edge
Trigger falling edge
Note that the P flag inverts the sense of the trigger input.
7.5
Trigger Output Option
This optional factory fitted option, when fitted can be used to trigger a camera. It can be used for
pulse width exposure control of the camera. The trigger timing for the light and camera can be
adjusted relative to each other.
This output is triggered at the same time as the light strobe output. The delay and pulse width for
this signal can be controlled independently of the light pulse.
7.6

Factory Settings

The default VTR1 configuration for the light output and trigger output are:
Pulse operation
1ms pulse width
0.01ms delay
50% intensity
30ms retrigger delay
The CL command can be used to restore the VTR1 to its default configuration.
Output
Pulse is triggered if P flag = 1
Pulse is triggered if P flag = 0